Electrical activity of the pulmonary vein and its interaction with the right atrium in the guinea‐pig.
Open accessAbstract
1. The tunica media of the proximal segments of the pulmonary vein is made up of cardiac muscle cells. The electrical activity of this cardiac portion of the pulmonary vein was studied with intracellular micro‐electrodes in isolated preparations. 2. All‐or‐none action potentials were recorded in all cardiac muscle cells in response to electrical stimulation. These action potentials did not propagate into the adjoining smooth muscle cells. 3. There were differences in properties between cells at the distal end of the cardiac pulmonary vein close to the smooth muscle and those close to the heart. In quiescent preparations, cells at the distal end had resting potentials which averaged 66 mV compared with 71 mV at proximal sites. Action potentials were also smaller and shorter in duration in cells at the distal end. 4. In spontaneously active preparations, pace‐making potentials were observed in cells at the distal end while cells close to the heart showed a stable diastolic potential between action potentials. The spontaneous activity of the pulmonary vein was influenced by both inhibitory and excitatory nerves. 5. The interaction between the pulmonary vein and atrial activities was studied in spontaneously active atrial‐pulmonary vein preparations. Action potentials recorded from the pulmonary vein always followed those from the right atrium. Electrical stimulation at the pulmonary vein generated action potentials that propagated back into the right atrium. 6. This study demonstrated that isolated pulmonary veins were capable of independent pace‐making activity. However the activity of the pulmonary vein was dominated by the SA node in atrial‐pulmonary vein preparations under normal conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
New ideas about atrial fibrillation 50 years on
Nattel, S. (2002) · Nature · doi:10.1038/415219a · Cited by 1,481
Chen, S.-A., Hsieh, M.-H., Tai, C.-T., Tsai, C.-F., Prakash, V. S., Yu, W.-C., Hsu, T.-L., Ding, Y.-A., & Chang, M.-S. (1999) · Circulation · doi:10.1161/01.cir.100.18.1879 · Cited by 1,446
Calkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Pathophysiological mechanisms of atrial fibrillation: a translational appraisal
Schotten, U., Verheule, S., Kirchhof, P., & Goette, A. (2011) · Physiological Reviews · doi:10.1152/physrev.00031.2009 · Cited by 1,273
Metadata
- Authors
- Cheung, D. W.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1981-05
- Volume
- 314
- Issue
- 1
- Pages
- 445-456
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2162780556
- Cited by
- 213
- References
- 0
- FWCI
- 0.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrical activity of the pulmonary vein and its interaction with the right atrium in the guinea‐pig. https://app.cochat.ai/papers/10.1113/jphysiol.1981.sp013718
- The paper
- Cheung, D. W. (1981). Electrical activity of the pulmonary vein and its interaction with the right atrium in the guinea‐pig. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1981.sp013718
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.