Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 184

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Elastic properties of the cat soleus tendon and their functional importance.

Open access
Rack, P M, Westbury, D R·1984·The Journal of Physiology

Abstract

A new method has been used to measure the stiffness of the entire tendinous component of the soleus muscle of the cat. During sinusoidal stretching of the muscle‐tendon combination, the motor nerves were stimulated repetitively in such a way that the force of contraction offset the movement, and the muscle fibres remained at constant length. The afferent endings of muscle spindles were used to detect extension of the muscle fibres. In this null situation, when the spindles did not 'see' any movement, all of the applied movement was assumed to have been taken up in the tendinous components, and measurements of the movement and force allowed the stiffness to be calculated. Precautions were taken to avoid the effects of fusimotor stimulation. The stiffness of the entire tendinous component increased with increasing muscle force by approximately 2 N/mm per Newton mean force from 2 N/mm at low force to about 25 N/mm at 11 N; the method could not be used for larger forces. Independent measurements of the stiffness of the external part of the tendon were made by both static and dynamic methods. The entire tendinous component was much less stiff than the external tendon. Measurements of the dimensions of the tendon allowed Young's modulus for the tendon to be calculated. It increased from about 250 N/mm2 at 2.5 N to about 450 N/mm2 at 10 N mean force. Measurements of dissected muscles allowed comparisons to be made between the stiffness of the external tendon and the stiffness of the entire tendinous component in the muscles. Scaling of the stiffness of the external part of the tendon to the length of the entire tendinous component gave a value of stiffness which was similar to that measured by the spindle null method. The compliance of tendons has implications for the control of movement which are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1984.sp015077

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 184

Metadata

Authors
Rack, P. M., & Westbury, D. R.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1984-02
Volume
347
Issue
1
Pages
479-495
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2129499227
Cited by
184
References
1
FWCI
12.27
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Elastic properties of the cat soleus tendon and their functional importance. https://app.cochat.ai/papers/10.1113/jphysiol.1984.sp015077
The paper
Rack, P. M., & Westbury, D. R. (1984). Elastic properties of the cat soleus tendon and their functional importance. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1984.sp015077

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.