Proprioceptors and normal tremor.
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The tremor of the hand, rotating about the wrist joint, was measured using an accelerometer, and groups of muscle action potentials were simultaneously recorded from the wrist extensor muscles using surface electrodes. The accelerometer signal and the rectified, demodulated electromyogram were submitted to Fourier analysis in order to quantify the tremor in terms of its frequency components and the amplitudes of those components. The amplitudes of the 8‐12 Hz peak in the frequency spectrum obtained from muscle electrical activity were compared (a) when the hand was held raised against gravity (i.e. the contraction was isotonic) with (b) when it was held raised, with the same force and in the same position against a rigid bar (i.e. the contraction was isometric). In the isotonic condition (a) a prominent 8‐12 Hz peak was observed in the spectrum. In the isometric condition (b) the peak was small or absent. The conclusion is drawn that the grouping (synchronization) of motor unit action potentials underlying tremor cannot be due to any process in the central nervous system generating them and they depend on cyclic alterations in muscle length activating proprioceptors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lippold, O. C. J. (1970) · The Journal of Physiology · doi:10.1113/jphysiol.1970.sp009018 · Cited by 286
Self-citationMechanical factors in human tremor frequency
Stiles, R. N., & Randall, J. E. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.23.3.324 · Cited by 191
Marshall, J., & Walsh, E. G. (1956) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.19.4.260 · Cited by 131
Cited by
Spinal and Supraspinal Factors in Human Muscle Fatigue
Gandevia, S. C. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.4.1725 · Cited by 3,645
Organization of motor output in slow finger movements in man.
Vallbo, A. B., & Wessberg, J. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019837 · Cited by 299
Burne, J. A., Hayes, M. W., Fung, V. S. C., Yiannikas, C., & Boljevac, D. (2002) · Journal of Clinical Neuroscience · doi:10.1054/jocn.2001.1017 · Cited by 51
Self-citationPassive mechanical properties of the wrist and physiological tremor.
Lakie, M., Walsh, E. G., & Wright, G. W. (1986) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.49.6.669 · Cited by 47
Héroux, M. E., Pari, G., & Norman, K. E. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.10.015 · Cited by 21
Metadata
- Authors
- Burne, J. A., Lippold, O. C., & Pryor, M.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1984-03
- Volume
- 348
- Issue
- 1
- Pages
- 559-572
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2142831289
- Cited by
- 38
- References
- 3
- FWCI
- 2.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Proprioceptors and normal tremor. https://app.cochat.ai/papers/10.1113/jphysiol.1984.sp015125
- The paper
- Burne, J. A., Lippold, O. C., & Pryor, M. (1984). Proprioceptors and normal tremor. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1984.sp015125
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.