Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 306

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

A non‐selective cation conductance in frog muscle membrane blocked by micromolar external calcium ions.

Open access
Almers, W, McCleskey, E W, Palade, P T·1984·The Journal of Physiology

Abstract

Membrane currents were recorded from voltage‐clamped, EGTA‐loaded muscle fibres under conditions where currents through ordinary Na+, K+ and Cl‐ channels were prevented by drugs or by absence of permeant ions (K+, and Cl‐). At 10 mM‐external [Ca2+], substitution of Na+ for the large and presumably impermeant organic cations tetramethyl‐ (TMA+) or tetraethylammonium (TEA+) failed to increase peak inward current. Hence the Ca2+ channel was not significantly permeable to Na+ under these conditions. When external [Ca2+] was reduced to levels below 1 microM in the presence of external Na+, step depolarizations to negative potentials produced tetrodotoxin‐resistant inward currents. At ‐20 mV, they rose to a peak of 30‐200 microA/cm2 within 150 ms and declined thereafter. Ca2+ and several other divalent cations reversibly blocked this inward current. The sequence of blocking potencies was Ca2+ greater than Sr2+ greater than or equal to Co2+ greater than Mn2+ congruent to Cd2+ greater than Ni2+ congruent to Mg2+. Large inward currents may be carried by Li+, Na+, K+, Rb+ and Cs+ but not by TMA+ and TEA+. The effect of external Ca2+ ([Ca2+]o) was explored over a 10(8)‐fold range in concentrations. Na+ was present at a fixed concentration. When [Ca2+]o was gradually increased from 10(‐10) to 10(‐2) M, inward current first diminished 10‐fold, reached a minimum at [Ca2+]o = 60 microM and then increased again as [Ca2+]o was increased further and Ca2+ itself became a current carrier. Block of inward current at [Ca2+]o less than 10(‐5) M could be described by binding of a single Ca2+ to a site, with a dissociation constant of the order of 0.7 microM at ‐20 mV.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1984.sp015351

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 306

Metadata

Authors
Almers, W., McCleskey, E. W., & Palade, P. T.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1984-08
Volume
353
Issue
1
Pages
565-583
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2169981344
Cited by
306
References
22
FWCI
7.03
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A non‐selective cation conductance in frog muscle membrane blocked by micromolar external calcium ions. https://app.cochat.ai/papers/10.1113/jphysiol.1984.sp015351
The paper
Almers, W., McCleskey, E. W., & Palade, P. T. (1984). A non‐selective cation conductance in frog muscle membrane blocked by micromolar external calcium ions. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1984.sp015351

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.