Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 560

The DOI matches its Crossref record.

Single‐channel recordings of three types of calcium channels in chick sensory neurones.

Open access
Fox, A P, Nowycky, M C, Tsien, R W·1987·The Journal of Physiology

Abstract

1. T‐, and L‐type Ca2+ channels were studied in cell‐attached patch recordings from the cell bodies of chick dorsal root ganglion neurones. All experiments were performed with isotonic BaCl2 (110 mM) in the recording pipette and with isotonic potassium aspartate in the bathing solution to zero the cell membrane potential. 2. L‐type channels are distinguished by a unitary slope conductance of 25 pS, activation over the range of membrane potentials between 0 and +40 mV, little inactivation over the course of a 136 ms depolarization, and availability for opening even at depolarized holding potentials (h.p. greater than ‐40 mV). L channels show a predominant mode of gating (mode 1) characterized by brief openings (approximately 1 ms), occasionally interspersed with another pattern of gating characterized by much longer openings (mode 2). 3. The dihydropyridine (DHP) Ca2+ agonist Bay K 8644 promotes mode 2 activity and shifts the voltage dependence of L‐type channel activation towards more negative potentials. It leaves the unitary current‐voltage relation unchanged. 4. Nifedipine, a DHP Ca2+ antagonist, strongly inhibits L‐type channel activity through an increase in the proportion of blank sweeps. 5. T‐type Ca2+ channels are distinguished by a much smaller unitary slope conductance (8 pS) and by activation and inactivation over relatively negative ranges of potential. Inactivation is complete by the end of 136 ms pulses to test potentials beyond ‐20 mV. 6. N‐type Ca2+ channels are distinguished by an intermediate unitary slope conductance (13 pS), and by activation over a range of potentials between those of T‐ and L‐type channels. Inactivation of N‐type channels takes place over an exceptionally broad range of holding potentials (‐80 to ‐20 mV). 7. Cell‐attached patch data on the voltage dependence of activation and inactivation of T‐ and N‐type channels are in excellent agreement with results from whole‐cell recordings (Fox, Nowycky & Tsien, 1987) if allowances are made for variations in external surface potential. 8. Patches containing one or two channels of a single type were used for analysis of gating kinetics. The predominant pattern of activity for each of the channel types is an exponential distribution of relatively brief (approximately 1 ms) openings, and a bi‐exponential distribution of short and long closings. 9. Patches containing all possible combinations of channel types were observed. However, preliminary evidence suggests that channels are distributed unevenly over the cell body; clustering of N‐type channels is particularly prominent.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1987.sp016865

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Fox, A. P., Nowycky, M. C., & Tsien, R. W.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1987-12
Volume
394
Issue
1
Pages
173-200
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2022513329
Cited by
560
References
0
FWCI
18.49
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.