Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 786

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Contribution of two types of calcium currents to the pacemaker potentials of rabbit sino‐atrial node cells.

Open access
Hagiwara, N, Irisawa, H, Kameyama, M·1988·The Journal of Physiology

Abstract

1. Two types of calcium currents, the transient type and long‐lasting type, were examined by both whole‐cell and cell‐attached patch‐clamp modes in single isolated sino‐atrial node cells of the rabbit. 2. In the whole‐cell clamp mode, in response to a depolarizing pulse to ‐40 mV from a holding potential of ‐80 mV, a transient type calcium current with an amplitude of 2.1 +/‐ 0.7 pA/pF (mean +/‐ S.D.; n = 15) was recorded. The threshold potential was approximately ‐50 mV. 3. Nickel (40 microM) and tetramethrin (0.1 microM) blocked the transient type calcium current without appreciable effects on the long‐lasting type. Nifedipine and D600 blocked the long‐lasting type, but did not affect the transient type. Cadmium (20 microM) and cobalt (2 mM) inhibited both types of calcium currents equally. 4. Both types of calcium currents showed an increased amplitude with increasing extracellular calcium concentration. The values of the Michaelis constant, Km, were 0.95 mM for the transient type and 3.92 mM for the long‐lasting type, indicating that these types represent two different classes of channels. 5. In the cell‐attached patch‐clamp mode, the single‐channel conductance of the transient type calcium current was 8.5 pS, by using 100 mM‐BaCl2 in the pipette, whereas that of the long‐lasting type was 16.0 pS, under the same conditions. Each of these values was similar to those found in other cells, respectively. 6. In the whole‐cell clamp mode, the transient type current began to inactivate at ‐70 mV and was fully inactivated at ‐40 mV. The steady‐state inactivation curve of the transient type current was approximately 50 mV negative to that of the long‐lasting type. The overlap of the membrane potential between the activation and inactivation curves was small. The time constant of the inactivation shortened from 20 to 5 ms as the potential became progressively positive over the range from ‐80 to +30 mV. 7. Isoprenaline (1 microM) increased the amplitude of the long‐lasting type Ca2+ current, but was not effective on the transient type, suggesting that the long‐lasting type calcium current may be responsible for the positive chronotropic effect of isoprenaline. 8. While recording spontaneous electrical activity of the cell, application of 40 microM‐nickel induced bradycardia and this effect was enhanced when the membrane was constantly hyperpolarized.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1988.sp016916

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 786

Metadata

Authors
Hagiwara, N., Irisawa, H., & Kameyama, M.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1988-01
Volume
395
Issue
1
Pages
233-253
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1983128983
Cited by
786
References
1
FWCI
32.17
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Contribution of two types of calcium currents to the pacemaker potentials of rabbit sino‐atrial node cells. https://app.cochat.ai/papers/10.1113/jphysiol.1988.sp016916
The paper
Hagiwara, N., Irisawa, H., & Kameyama, M. (1988). Contribution of two types of calcium currents to the pacemaker potentials of rabbit sino‐atrial node cells. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1988.sp016916

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.