Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 206

The DOI matches its Crossref record.

Control of light‐sensitive current in salamander rods.

Open access
Hodgkin, A L, Nunn, B J·1988·The Journal of Physiology

Abstract

1. The exponential decline of light‐sensitive current seen after switch from Na+ to Li+ in the presence of Ca2+ probably depends on the activity of the phosphodiesterase (PDE) which hydrolyses cyclic GMP. 2. This probability is supported by experiments with suction electrodes which show that in toad and salamander rods the rate constant, b, of the exponential decline of current was increased at least 10‐fold by moderate light intensities and decreased about 10‐fold by 3‐isobutyl‐1‐methylxanthine (IBMX), an inhibitor of PDE. 3. The rate constant b is about 3 times more sensitive to weak lights or to IBMX than the membrane current. This may be explained by a feed‐back involving calcium ions which tends to hold current constant, perhaps by calcium inhibition of guanylate cyclase. 4. The time course of b, which probably represents the changes in PDE activity, was measured by switching from Na+ to Li+ at various times after a flash. The results suggest that a moderate flash (140 Rh) increased b about 7 times in 0.5 s and that b then declined with a time constant of 1.5‐2 s. 5. Extrapolated values of the parameter b suggest that strong flashes (5000‐10,000 Rh) increased b from 1 s‐1 in the dark to perhaps 60 s‐1 and that b continued to increase with flash strength for several log units after the current had reached saturation. 6. The observations in 4 and 5 fit well with the idea that b is related to PDE activity and that changes in the latter are sufficient to account for the rising phase of the flash response. 7. After a flash the light‐sensitive current recovers much more rapidly than the time constant b‐1, a discrepancy which is explained if a light flash causes a delayed increase in guanylate cyclase activity. 8. The apparent delayed increase in cyclase activation is consistent with an inhibitory effect of [Ca2+]i which is reduced when calcium is pumped out during the plateau of the response. 9. Experiments in which pulses of IBMX were applied at different times during a flash response support the idea that a flash causes a delayed increase in the rate of supply of cyclic GMP. Quantitative analysis of these and other tests with IBMX gave rate constants similar to those obtained by the Na+‐‐‐‐Li+ method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1988.sp017258

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 206

Metadata

Authors
Hodgkin, A. L., & Nunn, B. J.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1988-09
Volume
403
Issue
1
Pages
439-471
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2004196814
Cited by
206
References
0
FWCI
4.19
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Control of light‐sensitive current in salamander rods. https://app.cochat.ai/papers/10.1113/jphysiol.1988.sp017258
The paper
Hodgkin, A. L., & Nunn, B. J. (1988). Control of light‐sensitive current in salamander rods. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1988.sp017258

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.