The DOI matches its Crossref record.
Synchronization of motor unit activity during voluntary contraction in man.
Open accessAbstract
1. Motor unit synchronization has been studied in human first dorsal interosseous muscle. 2. Two needle electrodes were inserted into the muscle and the activity of pairs of motor units recorded. 3. Pre‐ and post‐stimulus histograms of the firing of unit pairs showed a narrow central peak of duration 1.3‐9.3 ms (88% of sample in the range 1‐6 ms; mode 3.0 ms), together with a variable amount of synchronization of somewhat longer duration. 4. For the duration of the whole synchronization peak (85% sample in range 5‐15 ms; mode between 6.1 and 8.0 ms (31% of sample], units fired between 8 and 485% times more often than would have been expected had the units been firing independently of one another. Amplitudes of the peak of the recorded histograms expressed as a proportion of control ranged from 1.8 to 10.9 (mean 3.9; bin width 160 microseconds). 5. The strength of synchronization between the firing of motor unit pairs was inversely related to differences in recruitment threshold. The largest amount of synchronization was observed for pairs of units in which both had recruitment thresholds less than 0.5 N or greater than 1.0 N. Less synchronization was found between pairs of units in which one had a recruitment threshold less than 0.05 N and the other a threshold greater than 1.0 N. 6. The time course of synchronization was well matched by the predictions of a theoretical model based on the hypothesis that underlying the observed synchronization is the joint arrival of EPSPs from branched last‐order input fibres.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Conway, B. A., Halliday, D. M., Farmer, S. F., Shahani, U., Maas, P., Weir, A. I., & Rosenberg, J. R. (1995) · The Journal of Physiology · doi:10.1113/jphysiol.1995.sp021104 · Cited by 924
Sources of Signal-Dependent Noise During Isometric Force Production
Jones, K. E., Hamilton, A. F. D. C., & Wolpert, D. M. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.3.1533 · Cited by 562
Farmer, S. F., Bremner, F. D., Halliday, D. M., Rosenberg, J. R., & Stephens, J. A. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019851 · Cited by 514
Self-citationAment, W., & Verkerke, G. J. (2009) · Sports Medicine · doi:10.2165/00007256-200939050-00005 · Cited by 482
Yao, W., Fuglevand, R. J., & Enoka, R. M. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.1.441 · Cited by 473
Cortical Correlate of the Piper Rhythm in Humans
Brown, P., Salenius, S., Rothwell, J. C., & Hari, R. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.80.6.2911 · Cited by 405
Motor unit physiology: Some unresolved issues
Enoka, R. M., & Fuglevand, A. J. (2001) · Muscle & Nerve · doi:10.1002/1097-4598(200101)24:1<4::aid-mus13>3.0.co;2-f · Cited by 390
Training adaptations in the behavior of human motor units
Duchateau, J., Semmler, J. G., & Enoka, R. M. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00543.2006 · Cited by 354
EMGLAB: An interactive EMG decomposition program
McGill, K. C., Lateva, Z. C., & Marateb, H. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.05.015 · Cited by 317
How we Walk: Central Control of Muscle Activity during Human Walking
Nielsen, J. B. (2003) · The Neuroscientist · doi:10.1177/1073858403009003012 · Cited by 313
The scaling of motor noise with muscle strength and motor unit number in humans
de C. Hamilton, A. F., Jones, K. E., & Wolpert, D. M. (2004) · Experimental Brain Research · doi:10.1007/s00221-004-1856-7 · Cited by 287
Rhythmicity, synchronization and binding in human and primate motor systems
Farmer, S. F. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.003bo.x · Cited by 273
A Novel Framework Based on FastICA for High Density Surface EMG Decomposition
Chen, M., & Zhou, P. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2412038 · Cited by 260
Estimating the strength of common input to human motoneurons from the cross‐correlogram.
Nordstrom, M. A., Fuglevand, A. J., & Enoka, R. M. (1992) · The Journal of Physiology · doi:10.1113/jphysiol.1992.sp019244 · Cited by 259
Motor unit discharge and force tremor in skill- and strength-trained individuals
Semmler, J. G., & Nordstrom, M. A. (1998) · Experimental Brain Research · doi:10.1007/s002210050316 · Cited by 237
Metadata
- Authors
- Datta, A. K., & Stephens, J. A.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1990-03
- Volume
- 422
- Issue
- 1
- Pages
- 397-419
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2150980522
- Cited by
- 200
- References
- 0
- FWCI
- 6.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.