CoChat

Measurement of filtration coefficient in single cerebral microvessels of the frog.

Open access
Fraser, P A, Dallas, A D, Davies, S · 1990 · The Journal of Physiology
Cited by 52

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

1. This study reports the first results of measurements of filtration coefficient (Lp) and osmotic reflection coefficient to sucrose (sigma suc) in single brain microvessels. 2. Microvessels on the surface of frog brain were cannulated with a micropipette and perfused with an artificial cerebrospinal fluid (CSF) containing the low molecular weight impermeant dye carboxyfluorescein (MW 376). The superfusing solution was a similar CSF which could be made hypertonic by the addition of 40‐125 mmol l‐1 sucrose. 3. Vessels were assessed for dye retention using video‐intensified microscopy after occlusion with a glass microneedle. Only six vessels out of a total of ninety‐five were tight under the experimental conditions used. Those vessels which were tight were occluded while an osmotic load was applied across them. When this load was 50 mosmol l‐1 and less, the steady‐state dye concentration within the vessel lumen was similar to that predicted assuming the endothelium behaves as a perfect semipermeable membrane, with concentration polarization of solute. 4. The product Lp sigma was estimated in two ways: (i) from the fitted monoexponential function that described the rising dye concentration within the occluded segment, and (ii) from the initial rate of increase in dye concentration. The two values obtained were similar and it was concluded that sigma NaCl = sigma suc = 1, and the best estimate for filtration coefficient Lp = 2.0 x 10(‐9) cm (cmH2O s)‐1. 5. At the osmotic loads of 100 mosmol l‐1 and more, the initial rate of increase estimate of Lp sigma was less than half of the whole curve estimate, the axial dye distributions were dissimilar from those predicted by a mathematical model based on the perfect semipermeable membrane, and the steady‐state concentration was less than 70% of that expected. These findings are consistent with a diffusive pathway having opened. The model was modified to include patches of vessel wall which had developed leaks and a good fit to the data was obtained with a sucrose permeability and an Lp similar to skeletal muscle endothelium. 6. The possibility that water passes through a paracellular pathway across the intact blood‐brain barrier is discussed. It is concluded that this pathway could not be detected by the methods used and can carry no more than 50% of the water driven by a hydrostatic pressure gradient.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1990.sp018026

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Fraser, P. A., Dallas, A. D., & Davies, S.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1990-04
Volume
423
Issue
1
Pages
343-361
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2147936316
Cited by
52
References
2
FWCI
1.62
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.