The two power limits conditioning step frequency in human running.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
1. At high running speeds, the step frequency becomes lower than the apparent natural frequency of the body's bouncing system. This is due to a relative increase of the vertical component of the muscular push and requires a greater power to maintain the motion of the centre of gravity, Wext. However, the reduction of the step frequency leads to a decrease of the power to accelerate the limbs relatively to the centre of gravity, Wint, and, possibly, of the total power Wtot = Wext + Wint. 2. In this study we measured Wext using a force platform, Wint by motion picture analysis, and calculated Wtot during human running at six given speeds (from 5 to 21 km h‐1) maintained with different step frequencies dictated by a metronome. The power was calculated by dividing the positive work done at each step by the duration of the step (step‐average power) and by the duration of the positive work phase (push‐average power). 3. Also in running, as in walking, a change of the step frequency at a given speed has opposite effects on Wext, which decreases with increasing step frequency, and Wint, which increases with frequency; in addition, a step frequency exists at which Wtot reaches a minimum. However, the frequency for a minimum of Wtot decreases with speed in running, whereas it increases with speed in walking. This is true for both the step‐average and the push‐average powers. 4. The frequency minimizing the step‐average power equals the freely chosen step frequency at about 13 km h‐1: it is higher at lower speeds and lower at higher speeds. The frequency minimizing the push‐average power approaches the freely chosen step frequency at high speeds (around 22 km h‐1 for our subjects). 5. It is concluded that the increase of the vertical push does reduce the step‐average power, but that a limit is set by the increase of the push‐average power. Between 13 and 22 km h‐1 the freely chosen step frequency is intermediate between a frequency minimizing the step‐average power, eventually limited by the maximum oxygen intake (aerobic power), and a frequency minimizing the push‐average power, set free by the muscle immediately during contraction (anaerobic power). The first need prevails at the lower speed, the second at the higher speed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energetics of running: a new perspective
Kram, R., & Taylor, C. R. (1990) · Nature · doi:10.1038/346265a0 · Cited by 821
Cited by
Migueles, J. H., Cadenas-Sanchez, C., Ekelund, U., Delisle Nyström, C., Mora-Gonzalez, J., Löf, M., Labayen, I., Ruiz, J. R., & Ortega, F. B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0716-0 · Cited by 1,868
Leg stiffness and stride frequency in human running
Farley, C. T., & González, O. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00029-1 · Cited by 737
Dorn, T. W., Schache, A. G., & Pandy, M. G. (2012) · Journal of Experimental Biology · doi:10.1242/jeb.064527 · Cited by 535
Running economy: Measurement, norms, and determining factors
Barnes, K. R., & Kilding, A. E. (2015) · Sports Medicine - Open · doi:10.1186/s40798-015-0007-y · Cited by 465
“[13,104,165-167].”
External, Internal and Total Work in Human Locomotion
Willems, P. A., Cavagna, G. A., & Heglund, N. C. (1995) · Journal of Experimental Biology · doi:10.1242/jeb.198.2.379 · Cited by 405
Self-citationReexamination of Validity and Reliability of the CSA Monitor in Walking and Running
BRAGE, S., WEDDERKOPP, N., FRANKS, P. W., BO ANDERSEN, L., & FROBERG, K. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000079078.62035.ec · Cited by 347
Biomechanics and Running Economy
Anderson, T. (1996) · Sports Medicine · doi:10.2165/00007256-199622020-00003 · Cited by 309
Energetically optimal stride frequency in running: the effects of incline and decline
Snyder, K. L., & Farley, C. T. (2011) · Journal of Experimental Biology · doi:10.1242/jeb.053157 · Cited by 124
Metadata
- Authors
- Cavagna, G. A., Willems, P. A., Franzetti, P., & Detrembleur, C.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1991-06
- Volume
- 437
- Issue
- 1
- Pages
- 95-108
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1988384904
- Cited by
- 105
- References
- 1
- FWCI
- 0.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.