The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Reexamination of Validity and Reliability of the CSA Monitor in Walking and Running
Abstract
PURPOSE: To evaluate the reliability and validity of the CSA (model 7164) accelerometer (MTI) in a wide walking-running speed range in laboratory and field. METHOD: Twelve male subjects performed three treadmill walking/running sessions and one field trial with the same continuous protocol involving progressively increasing velocities at 5 min per interval from 3 to 6 km x h(-1) (walking) and 8 to 20 km x h(-1) (running). In the field trial, this protocol was terminated after 35 min (14 km.h(-1)), but the trial then extended with 5-km running at a freely chosen velocity. In both scenarios, two CSAs were mounted on each hip and the step frequency measured at each velocity. Oxygen uptake VO(2) x kg(-1) was measured on the last two treadmill sessions. Correlation analyses were performed for mean CSA output relationship with speed, VO(2) per kilogram, and step frequency. RESULTS: In all trials, CSA output rose linearly (R2 = 0.92, P < 0.001) with increasing speed until 9 km.h-1 but remained at approximately 10000 counts.min-1 during running, thus underestimating VO(2) per kilogram at speeds > 9 km x h(-1). Estimation errors increased with speed from 11% (P < 0.01) at 10 km x h(-1) to 48% (P < 0.001) at 16 km x h(-1), when assuming a linear relationship. Freely chosen velocities in the field trial ranged from 10.9 to 16.3 km.h-1. No difference in the CSA-speed relationship was observed between the two scenarios. Differences in CSA output between subjects could partially be attributed to differences in step frequency (R = -0.34 (P = 0.02) for walking and R = -0.63 (P < 0.001) for running). CONCLUSION: CSA output increases linearly with speed in the walking range but not in running, presumably due to relatively constant vertical acceleration in running. Between-subject reliability was related to step frequency because CSA data are filtered most at higher movement frequencies. Epidemiological CSA data should thus be interpreted with these limitations in mind.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
External, Internal and Total Work in Human Locomotion
Willems, P. A., Cavagna, G. A., & Heglund, N. C. (1995) · Journal of Experimental Biology · doi:10.1242/jeb.198.2.379 · Cited by 405
A combined heart rate and movement sensor: proof of concept and preliminary testing study
Rennie, K., Rowsell, T., Jebb, S., Holburn, D., & Wareham, N. (2000) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600973 · Cited by 83
Cited by
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638
Calibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677
Validation and comparison of ActiGraph activity monitors
Sasaki, J. E., John, D., & Freedson, P. S. (2011) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2011.04.003 · Cited by 1,317
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Physical Activity in U.S. Adults
Tucker, J. M., Welk, G. J., & Beyler, N. K. (2011) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2010.12.016 · Cited by 977
Metadata
- Authors
- BRAGE, S., WEDDERKOPP, N., FRANKS, P. W., BO ANDERSEN, L., & FROBERG, K.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2003-08
- Volume
- 35
- Issue
- 8
- Pages
- 1447-1454
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2089180972
- Cited by
- 347
- References
- 4
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reexamination of Validity and Reliability of the CSA Monitor in Walking and Running. https://app.cochat.ai/papers/10.1249/01.mss.0000079078.62035.ec
- The paper
- BRAGE, S., WEDDERKOPP, N., FRANKS, P. W., BO ANDERSEN, L., & FROBERG, K. (2003). Reexamination of Validity and Reliability of the CSA Monitor in Walking and Running. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000079078.62035.ec
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.