Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 190

The DOI matches its Crossref record.

Plasma proteins modify the endothelial cell glycocalyx of frog mesenteric microvessels.

Open access
Adamson, R H, Clough, G·1992·The Journal of Physiology

Abstract

1. We have investigated the interaction of plasma proteins with the endothelial cell using cationized ferritin as a marker of the cell surface glycocalyx. 2. Single microvessels of the frog mesentery were sequentially perfused using glass micropipettes with solutions containing cationized ferritin (CF, 6.7 mg ml‐1) in 0.10 M‐NaCl and then with either frog plasma or bovine serum albumin (BSA; 50 or 10 mg ml‐1), or protein‐free Ringer solution, before suffusion fixation in 2.5% glutaraldehyde. 3. A layer of CF, usually two to four molecules thick, was associated with the luminal endothelial cell surface. In vessels post‐flushed with protein‐free Ringer solution the CF layer was closely adherent to all regions of the luminal endothelium, including the plasma membrane, vesicle diaphragms, coated pits and the entrances to clefts. However, when plasma was present during fixation the CF layer was separated from the cell surface by up to 100 nm over all regions. In vessels post‐flushed with BSA the CF layer was also separated from the membrane but the effect was less striking. 4. The association of cationized ferritin with the endothelial cell surface was assessed quantitatively using electron micrographs of transverse sections (approximately 50 nm thick) of the perfused vessels, and expressed in terms of the depth of the layer of CF associated with the endothelial cell surface, its separation from the plasma membrane of the luminal endothelium, and the concentration of CF in the layer. The mean (+/‐ S.D.) separation in the presence of plasma, 32.3 +/‐ 10.5 nm (n = 12), was significantly greater (P less than 0.01) than that with either protein‐free Ringer solution, 3.0 +/‐ 1.4 nm (n = 9), or BSA in Ringer solution, 8.3 +/‐ 3.0 nm (n = 8). The separation seen with BSA in Ringer was also significantly greater than that measured with a final Ringer solution perfusion (P less than 0.01). The effects of 10 and 50 mg ml‐1 BSA were not different from one another. The total glycocalyx thickness, defined as the sum of the separation layer and depth of CF layer, with plasma present, 56.2 +/‐ 13.7 nm, was twice the value seen with Ringer solution, 28.0 +/‐ 9.1 nm (P less than 0.01), while the total thickness with BSA, 30.9 +/‐ 5.4 nm, was not different from the Ringer solution value.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1992.sp018934

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 190

Metadata

Authors
Adamson, R. H., & Clough, G.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1992-01
Volume
445
Issue
1
Pages
473-486
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2033576968
Cited by
190
References
0
FWCI
0.62
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Plasma proteins modify the endothelial cell glycocalyx of frog mesenteric microvessels. https://app.cochat.ai/papers/10.1113/jphysiol.1992.sp018934
The paper
Adamson, R. H., & Clough, G. (1992). Plasma proteins modify the endothelial cell glycocalyx of frog mesenteric microvessels. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1992.sp018934

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.