Co‐ordination of pumping in isolated bovine lymphatic vessels.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
1. Segments of bovine mesenteric lymphatic of varying diameter taken from different parts of the lymphatic tree were cut to 20 mm in length and set up so that measurements could be made of spontaneous isometric contractions. 2. There was considerable variability in frequency of spontaneous contractions but this was independent of resting tension. There was no significant correlation between lymphatic diameter and inherent frequency of contraction. 3. Isolated segments of bovine mesenteric lymphatic 70‐80 mm in length were cannulated and set up in a three‐compartment organ bath which allowed independent temperature control in each compartment. Pressure was recorded at inflow and outflow ends and experiments were video recorded. 4. Contractile activity was normally initiated at the end of the lymphatic maintained at the higher temperature and the contractile wave was propagated along the length of the vessel. 5. Propagation could occur either in the direction of valve orientation (orthograde) or retrogradely. The volume of fluid pumped was not significantly affected by the direction of propagation. 6. Perfusion of the central compartment with Krebs solution at 0‐2 degrees C disrupted normal propagation and allowed the two parts of the lymphatic to contract at different frequencies although the two parts maintained an approximately 2:1 ratio. 7. Perfusion of the central compartment with 10 mM‐heptanol also disrupted normal propagation but the rates on either side of the partition bore no harmonic relationship to one another. 8. These results suggest that relatively short segments of lymph duct have the ability to contract spontaneously and that their inherent frequencies are not determined by their position in the lymphatic tree. The results are consistent with the existence of electrical coupling along the lymphatic's length and they suggest that over distances of at least 80 mm independent pacemakers are capable of mutual entrainment at a frequency representing a compromise between the fastest and slowest components.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intrinsic contractility of prenodal lymph vessels and lymph flow in human leg
Olszewski, W. L., & Engeset, A. (1980) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1980.239.6.h775 · Cited by 201
Cited by
Lymphatic pumping: mechanics, mechanisms and malfunction
Scallan, J. P., Zawieja, S. D., Castorena‐Gonzalez, J. A., & Davis, M. J. (2016) · The Journal of Physiology · doi:10.1113/jp272088 · Cited by 424
“In mesenteric lymphatic vessel segments studied either ex vivo or in vivo, the application of gap-junction blockers (e.g. n-heptanol, oleic acid) leads to uncoordinated contractions of different parts of a lymphatic chain (McHale & Meharg, 1992; Zawieja et al. 1993).”
BackgroundInfluentialContractile Physiology of Lymphatics
Zawieja, D. C. (2009) · Lymphatic Research and Biology · doi:10.1089/lrb.2009.0007 · Cited by 368
Modelling the lymphatic system: challenges and opportunities
Margaris, K. N., & Black, R. A. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0751 · Cited by 229
Molecular and functional analyses of the contractile apparatus in lymphatic muscle
Muthuchamy, M., Gashev, A., Boswell, N., Dawson, N., & Zawieja, D. (2003) · The FASEB Journal · doi:10.1096/fj.02-0626fje · Cited by 205
Pacemaker potentials in lymphatic smooth muscle of the guinea‐pig mesentery.
Van Helden, D. F. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019910 · Cited by 193
Metadata
- Authors
- McHale, N. G., & Meharg, M. K.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1992-05
- Volume
- 450
- Issue
- 1
- Pages
- 503-512
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2057245677
- Cited by
- 103
- References
- 1
- FWCI
- 0.31
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.