The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Estimating the strength of common input to human motoneurons from the cross‐correlogram.
Open accessAbstract
1. The relationship between the motor unit discharge pattern (rate and variability) and synchronization of motor unit pairs was studied in the first dorsal interosseus muscle of human subjects. In separate trials of up to 4 min duration, subjects voluntarily controlled the mean discharge rate of an identified motor unit at one of several prescribed rates (range 7.5‐17.5 Hz). 2. The effect of discharge rate on the synchronous peak in the cross‐correlogram was examined in eighty motor unit pairs from six subjects. Five commonly used synchronization indices were used to quantify synchrony in the cross‐correlograms constructed from different discharge‐rate trials. For each synchronization index, the apparent magnitude of synchrony increased at lower motor unit discharge rates. The synchronization indices were not equally sensitive to discharge rate; increases in the different indices ranged from 72 to 494% between the highest and lowest discharge rates. 3. A model of the membrane potential trajectory underlying rhythmic motoneuron discharge was used to explain the observed increase in the magnitude of the synchronization indices at lower discharge rates. The essential feature of this model is that the probability of a common‐input EPSP causing a synchronous discharge in two motoneurons is independent of discharge rate. This means that the number of synchronous action potentials in excess of chance in any trial depends on the properties of the common‐input EPSPs and the duration of the trial, but is not related to motor unit discharge rates. The model also demonstrated that when the excess synchronous counts are normalized to motor unit discharge rate, or baseline counts in the histogram (as in the conventional synchronization indices), the magnitude of the index increases when the motor unit discharge rates are low. 4. The strength of common input to motoneurons could be misinterpreted if conventional synchronization indices are used because of discharge‐rate effects. The model was used to derive an index of the strength of common input to motoneurons (CIS) that was independent of motor unit discharge rate. CIS is the frequency of synchronous action potentials in the motor unit pair in excess of those expected due to chance (calculated during periods of tonic discharge in both units). The mean CIS in first dorsal interosseus motor unit pairs ranged from 0.052 to 1.005 extra synchronous action potentials per second across subjects. 5. Discharge variability was correlated with each of the synchronization indices and the CIS.(ABSTRACT TRUNCATED AT 400 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cumulative sum technique and its application to the analysis of peristimulus time histograms
Ellaway, P. H. (1978) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(78)90017-2 · Cited by 451
Statistical Analysis and Functional Interpretation of Neuronal Spike Data
Moore, G. P., Perkel, D. H., & Segundo, J. P. (1966) · Annual Review of Physiology · doi:10.1146/annurev.ph.28.030166.002425 · Cited by 435
Short‐term synchronization of intercostal motoneurone activity.
Sears, T. A., & Stagg, D. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011635 · Cited by 387
Synaptic noise and other sources of randomness in motoneuron interspike intervals.
Calvin, W. H., & Stevens, C. F. (1968) · Journal of Neurophysiology · doi:10.1152/jn.1968.31.4.574 · Cited by 358
Fetz, E. E., & Gustafsson, B. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014812 · Cited by 290
Kirkwood, P. A. (1979) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(79)90009-8 · Cited by 264
Kirkwood, P. A., & Sears, T. A. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012180 · Cited by 224
Synchronization of motor unit activity during voluntary contraction in man.
Datta, A. K., & Stephens, J. A. (1990) · The Journal of Physiology · doi:10.1113/jphysiol.1990.sp017991 · Cited by 200
Factors influencing motoneuron rhythmic firing: results from a voltage-clamp study
Schwindt, P. C., & Crill, W. E. (1982) · Journal of Neurophysiology · doi:10.1152/jn.1982.48.4.875 · Cited by 175
Task and fatigue effects on low-threshold motor units in human hand muscle
Enoka, R. M., Robinson, G. A., & Kossev, A. R. (1989) · Journal of Neurophysiology · doi:10.1152/jn.1989.62.6.1344 · Cited by 160
Self-citationDatta, A. K., Farmer, S. F., & Stephens, J. A. (1991) · The Journal of Physiology · doi:10.1113/jphysiol.1991.sp018391 · Cited by 151
Variations in the time course of the synchronization of intercostal motoneurones in the cat
Kirkwood, P., Sears, T. A., Tuck, D. L., & Westgaard, R. H. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014223 · Cited by 141
Cope, T. C., Fetz, E. E., & Matsumura, M. (1987) · The Journal of Physiology · doi:10.1113/jphysiol.1987.sp016692 · Cited by 127
Generation of spike trains in CNS neurons
Calvin, W. H. (1975) · Brain Research · doi:10.1016/0006-8993(75)90796-9 · Cited by 120
Bremner, F. D., Baker, J. R., & Stephens, J. A. (1991) · The Journal of Physiology · doi:10.1113/jphysiol.1991.sp018389 · Cited by 120
Membrane-potential trajectories between spikes underlying motoneuron firing rates.
Schwindt, P. C., & Calvin, W. H. (1972) · Journal of Neurophysiology · doi:10.1152/jn.1972.35.3.311 · Cited by 120
Three modes of repetitive firing and the role of threshold time course between spikes
Calvin, W. H. (1974) · Brain Research · doi:10.1016/0006-8993(74)90012-2 · Cited by 115
Influence of stretch‐evoked synaptic potentials on firing probability of cat spinal motoneurones.
Gustafsson, B., & McCrea, D. A. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015074 · Cited by 106
Bremner, F. D., Baker, J. R., & Stephens, J. A. (1991) · The Journal of Physiology · doi:10.1113/jphysiol.1991.sp018390 · Cited by 106
Motor unit firing rates and firing rate variability in the detection of neuromuscular disorders
Dorfman, L. J., Howard, J. E., & McGill, K. C. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90122-3 · Cited by 69
Adams, L. M., Datta, A. K., & Guz, A. (1989) · The Journal of Physiology · doi:10.1113/jphysiol.1989.sp017650 · Cited by 64
Schwindt, P. C., & Calvin, W. H. (1973) · Brain Research · doi:10.1016/0006-8993(73)90278-3 · Cited by 61
A stable, selective electrode for recording single motor-unit potentials in humans
Enoka, R. M., Robinson, G. A., & Kossev, A. R. (1988) · Experimental Neurology · doi:10.1016/0014-4886(88)90189-6 · Cited by 43
Self-citation
Cited by
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573
Self-citationMechanisms that contribute to differences in motor performance between young and old adults
Enoka, R. M., Christou, E. A., Hunter, S. K., Kornatz, K. W., Semmler, J. G., Taylor, A. M., & Tracy, B. L. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00084-6 · Cited by 562
Self-citationYao, W., Fuglevand, R. J., & Enoka, R. M. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.1.441 · Cited by 473
Self-citationMoritz, C. T., Barry, B. K., Pascoe, M. A., & Enoka, R. M. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01122.2004 · Cited by 429
Self-citationSteadiness is reduced and motor unit discharge is more variable in old adults
Laidlaw, D. H., Bilodeau, M., & Enoka, R. M. (2000) · Muscle & Nerve · doi:10.1002/(sici)1097-4598(200004)23:4<600::aid-mus20>3.0.co;2-d · Cited by 427
Self-citation
Metadata
- Authors
- Nordstrom, M. A., Fuglevand, A. J., & Enoka, R. M.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1992-07
- Volume
- 453
- Issue
- 1
- Pages
- 547-574
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2055888932
- Cited by
- 259
- References
- 23
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.