CoChat

Responses of macaque ganglion cells to the relative phase of heterochromatically modulated lights.

Open access
Smith, V C, Lee, B B, Pokorny, J, Martin, P R, Valberg, A · 1992 · The Journal of Physiology
Cited by 196

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

1. We measured the response of macaque ganglion cells to sinusoidally modulated red and green lights as the relative phase, theta, of the lights was varied. 2. At low frequencies, red‐green ganglion cells of the parvocellular (PC‐) pathway with opponent inputs from middle‐wavelength sensitive (M‐) and long‐wavelength sensitive (L‐) cones were minimally sensitive to luminance modulation (theta = 0 deg) and maximally sensitive to chromatic modulation (theta = 180 deg). With increasing frequency, the phase, theta, of minimal amplitude gradually changed, in opposite directions for cells with M‐ and L‐cone centres. 3. At high frequencies (at and above 20 Hz), phasic cells of the magnocellular (MC‐) pathway were maximally responsive when theta approximately 0 deg and minimally responsive when theta approximately 180 deg, as expected from an achromatic mechanism. At lower frequencies, the phase of minimal response shifted, for both on‐ and off‐centre cells, to values of theta intermediate between 0 and 180 deg. This phase asymmetry was absent if the centre alone was stimulated with a small field. 4. For PC‐pathway cells, it was possible to provide an account of response phase as a function of theta, using a model involving three parameters; phases of the L‐ and M‐cone mechanisms and a L/M cone weighting term. For red‐green cells, the phase parameters were monotonically related to temporal frequency and revealed a centre‐surround phase difference. The phase difference was linear with a slope of 1‐3 deg Hz‐1. If this represents a latency difference, it would be 3‐8 ms. Otherwise, temporal properties of the M‐ and L‐cones appeared similar if not identical. By addition of a scaling term, the model could be extended to give an adequate account of the amplitude of responses. 5. We were able to activate selectively the surrounds of cells with short‐wavelength (S‐) cone input to their centres, and so were able to assess L/M cone weighting to the surround. M‐ and L‐cone inputs added linearly for most cells. On average, the weighting corresponded to the Judd modification of the luminosity function although there was considerable inter‐cell variability. 6. To account for results from MC‐pathway cells, it was necessary to postulate a cone‐opponent, chromatic input to their surrounds. We developed a receptive field model with linear summation of M‐ and L‐cones to centre and surround, and with an additional M,L‐cone opponent input to the surround.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1992.sp019413

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 196

Metadata

Authors
Smith, V. C., Lee, B. B., Pokorny, J., Martin, P. R., & Valberg, A.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1992-12
Volume
458
Issue
1
Pages
191-221
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2091516658
Cited by
196
References
1
FWCI
3.84
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.