The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Magnetic coil stimulation of straight and bent amphibian and mammalian peripheral nerve in vitro: locus of excitation.
Open accessAbstract
1. According to classical cable theory, a magnetic coil (MC) should excite a linear nerve fibre in a homogeneous medium at the negative‐going first spatial derivative of the induced electric field. This prediction was tested by MC stimulation of mammalian phrenic and amphibian sciatic nerve and branches in vitro, immersed in Ringer solution within a trough, and identifying the sites of excitation by recording responses of similar latency to local electrical stimulation. Subsequently, the identified sites of excitation were compared with measurements of the induced electric field and its calculated first spatial derivative. A special hardware device was used to selectively reverse MC current direction and to generate predominantly monophasic‐ or polyphasic‐induced pulse profiles whose initial phases were identical in polarity, shape and amplitude. When using the amphibian nerve preparation, a complication was excitation at low threshold points related to cut branches. 2. Reversal of monophasic current resulted in latency shifts corresponding approximately to the distance between induced cathode and anode. The location of each site of excitation was at, or very near, the negative‐going first spatial derivative peaks of the induced electric field measured parallel to the straight nerve. Significantly, excitation of the nerve did not occur at the peak of the induced electric field above the centre of the ‘figure of eight’ MC junction. 3. A polyphasic pulse excited the nerve at both sites, by the negative‐going first phase at one location, and approximately 150 microseconds later, by the reversed negative‐going second phase at the other location. Polyphasic and monophasic pulses elicited responses with similar latency when the induced current flowed towards the recording electrode. 4. Straddling a nerve with non‐coding solid lucite cylinders created a localized spatial narrowing and increase in the induced electric field, resulting in a lowered threshold of excitation. The corresponding closer spacing between first spatial derivative peaks was exhibited by a significant reduction in latency shift when MC current direction was reversed. 5. When a nerve is bent and the induced current is directed along the nerve towards the bend, the threshold of excitation is reduced there. Increasing the angle of the bend from 0 deg to more than 90 deg graded the decrease in threshold. 6. In a straight nerve the threshold was lowest when current was directed towards the cut end.(ABSTRACT TRUNCATED AT 400 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Models for External Stimulation of Axons
Rattay, F. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325670 · Cited by 681
Suppression of visual perception by magnetic coil stimulation of human occipital cortex
Amassian, V. E., Cracco, R. Q., Maccabee, P. J., Cracco, J. B., Rudell, A., & Eberle, L. (1989) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(89)90036-1 · Cited by 558
Self-citationEffects of coil design on delivery of focal magnetic stimulation. Technical considerations
Cohen, L. G., Roth, B. J., Nilsson, J., Dang, N., Panizza, M., Bandinelli, S., Friauf, W., & Hallett, M. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90113-x · Cited by 409
A model of the stimulation of a nerve fiber by electromagnetic induction
Roth, B. J., & Basser, P. J. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55662 · Cited by 363
Peripheral nerve stimulation by induced electric currents: Exposure to time-varying magnetic fields
Reilly, J. P. (1989) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446217 · Cited by 293
Magnetic stimulation over the spinal enlargements.
Ugawa, Y., Rothwell, J. C., Day, B. L., Thompson, P. D., & Marsden, C. D. (1989) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.52.9.1025 · Cited by 185
Developing a More Focal Magnetic Stimulator. Part I: Some Basic Principles
Cohen, D., & Cuffin, B. N. (1991) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199101000-00013 · Cited by 159
The distribution of induced currents in magnetic stimulation of the nervous system
Tofts, P. S. (1990) · Physics in Medicine and Biology · doi:10.1088/0031-9155/35/8/008 · Cited by 159
Stimulation of a myelinated nerve axon by electromagnetic induction
Basser, P. J., & Roth, B. J. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446708 · Cited by 151
Maccabee, P. J., Amassian, V. E., Eberle, L., Rudell, A. P., Cracco, R. Q., Lai, K., & Somasundarum, M. (1991) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(91)90076-a · Cited by 120
Self-citation
Cited by
Rossi, S., Hallett, M., Rossini, P. M., & Pascual-Leone, A. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.08.016 · Cited by 5,367
Rossini, P. M., Burke, D., Chen, R., Cohen, L. G., Daskalakis, Z., Di Iorio, R., Di Lazzaro, V., Ferreri, F., Fitzgerald, P. B., George, M. S., et al. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.02.001 · Cited by 2,753
Transcranial magnetic stimulation in neurology
Kobayashi, M., & Pascual-Leone, A. (2003) · The Lancet Neurology · doi:10.1016/s1474-4422(03)00321-1 · Cited by 1,297
A practical guide to diagnostic transcranial magnetic stimulation: Report of an IFCN committee
Groppa, S., Oliviero, A., Eisen, A., Quartarone, A., Cohen, L. G., Mall, V., Kaelin-Lang, A., Mima, T., Rossi, S., Thickbroom, G. W., et al. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2012.01.010 · Cited by 1,274
Deng, Z.-D., Lisanby, S. H., & Peterchev, A. V. (2013) · Brain Stimulation · doi:10.1016/j.brs.2012.02.005 · Cited by 1,073
Metadata
- Authors
- Maccabee, P. J., Amassian, V. E., Eberle, L. P., & Cracco, R. Q.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1993-01
- Volume
- 460
- Issue
- 1
- Pages
- 201-219
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2001071167
- Cited by
- 321
- References
- 14
- FWCI
- 3.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic coil stimulation of straight and bent amphibian and mammalian peripheral nerve in vitro: locus of excitation. https://app.cochat.ai/papers/10.1113/jphysiol.1993.sp019467
- The paper
- Maccabee, P. J., Amassian, V. E., Eberle, L. P., & Cracco, R. Q. (1993). Magnetic coil stimulation of straight and bent amphibian and mammalian peripheral nerve in vitro: locus of excitation. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1993.sp019467
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.