Matching between motoneurone and muscle unit properties in rat medial gastrocnemius.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
1. Electrical and contractile (isometric) properties were studied for sixty‐six motoneurone‐muscle unit combinations from rat medial gastrocnemius (MG). The animals were anaesthetized with pentobarbitone. 2. The muscle units were classified into S (slow) and F (fast) on the basis of measurements of speed and fatigue resistance: the 'slow' category comprised units with an initial twitch contraction time exceeding those found among fatigue‐sensitive units (border value 20 ms). 3. Twitch speed was assessed by three different measures: (i) contraction time (time to peak, range 11.4‐28.0 ms), (ii) half‐relaxation time (8.4‐56.5 ms), and (iii) total twitch duration (34‐116 ms). All three measures were mutually highly correlated and their respective values showed a continuous and unimodal distribution across the unit population. 4. The motoneurones were investigated with regard to their time course and amplitude of post‐spike after‐hyperpolarization (AHP; range of total durations 30‐116 ms, amplitudes 0.9‐8.0 mV), rheobase (0.8‐17.1 nA), input resistance (0.8‐5.1 M omega) and axonal conduction velocity (33‐85 m/s). 5. Motoneurones of slow‐twitch muscle units (type S) had, on average, a significantly slower time course of AHP, a smaller rheobase, a higher input resistance and more slowly conducting axons than those innervating fast‐twitch muscle units. 6. Across the whole neuronal sample, input conductance (reciprocal of input resistance) correlated well with rheobase (r = 0.74). However, the differences in rheobase did not seem to be caused exclusively by the associated differences in input conductance. 7. Throughout the sampled population, the relative slowness of AHP showed a continuous and highly significant correlation with the relative slowness of the corresponding unit twitch. The absolute duration of AHP was close to that of the twitch. In the Discussion it is argued that this 'speed match' between motoneurone and muscle unit would help ensure that barely recruited motoneurones start firing at a frequency that is optimally suited for the subsequent rate gradation of force. 8. AHP amplitude was, on average, significantly smaller for fast‐twitch than for slow‐twitch motoneurones. Calculations indicated that these differences were almost completely caused by the associated differences in input resistance; the computed value for the conductance change underlying the AHP was nearly the same for fast‐ and slow‐twitch motoneurones. 9. A simple neurone model was used to calculate the consequences of the differences in AHP amplitude and duration for repetitive discharge properties of fast and slow cell categories.(ABSTRACT TRUNCATED AT 400 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Factors causing difference in force output among motor units in the rat medial gastrocnemius muscle
Kanda, K., & Hashizume, K. (1992) · The Journal of Physiology · doi:10.1113/jphysiol.1992.sp019064 · Cited by 156
Cited by
Motor Neuron Diversity in Development and Disease
Kanning, K. C., Kaplan, A., & Henderson, C. E. (2010) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135722 · Cited by 478
Heckman, C. J., & Enoka, R. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100087 · Cited by 414
Motor unit physiology: Some unresolved issues
Enoka, R. M., & Fuglevand, A. J. (2001) · Muscle & Nerve · doi:10.1002/1097-4598(200101)24:1<4::aid-mus13>3.0.co;2-f · Cited by 390
Training adaptations in the behavior of human motor units
Duchateau, J., Semmler, J. G., & Enoka, R. M. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00543.2006 · Cited by 354
Motor unit firing rates and contractile properties in tibialis anterior of young and old men
Connelly, D. M., Rice, C. L., Roos, M. R., & Vandervoort, A. A. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.2.843 · Cited by 340
“These studies support the concept of matching (1) between parent motoneuron firing rates and their constituent muscle fiber contractile properties.”
BackgroundResultDe Luca, C. J., & Hostage, E. C. (2010) · Journal of Neurophysiology · doi:10.1152/jn.01018.2009 · Cited by 326
EPHA4 is a disease modifier of amyotrophic lateral sclerosis in animal models and in humans
Van Hoecke, A., Schoonaert, L., Lemmens, R., Timmers, M., Staats, K. A., Laird, A. S., Peeters, E., Philips, T., Goris, A., Dubois, B., et al. (2012) · Nature Medicine · doi:10.1038/nm.2901 · Cited by 303
Bistability in Spinal Motoneurons In Vivo: Systematic Variations in Rhythmic Firing Patterns
Lee, R. H., & Heckman, C. J. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.80.2.572 · Cited by 274
Orderly recruitment of motor units under optical control in vivo
Llewellyn, M. E., Thompson, K. R., Deisseroth, K., & Delp, S. L. (2010) · Nature Medicine · doi:10.1038/nm.2228 · Cited by 217
Motor Neuron Susceptibility in ALS/FTD
Ragagnin, A. M. G., Shadfar, S., Vidal, M., Jamali, M. S., & Atkin, J. D. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00532 · Cited by 214
The Physiological Control of Motoneuron Activity
Binder, M. D., Heckman, C. J., & Powers, R. K. (1996) · Comprehensive Physiology · doi:10.1002/cphy.cp120101 · Cited by 172
Enhancement of Bistability in Spinal Motoneurons In Vivo by the Noradrenergic α1 Agonist Methoxamine
Lee, R. H., & Heckman, C. J. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.81.5.2164 · Cited by 161
“…important because motoneurons with low input conductances tend to innervate slow twitch, fatigue resistant muscle units, whereas high input conductance motoneurons tend to innervate fast twitch, fatiguable muscle units (Bakels and Kernell 1993; Burke et al. 1973; Gardiner 1993; Zengel et al. 1985).”
Background
Metadata
- Authors
- Bakels, R., & Kernell, D.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1993-04
- Volume
- 463
- Issue
- 1
- Pages
- 307-324
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2069134696
- Cited by
- 127
- References
- 1
- FWCI
- 4.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.