A reassessment of mercury in silastic strain gauge plethysmography for microvascular permeability assessment in man.
Open accessThe DOI matches its Crossref record.
Abstract
1. We have used non‐invasive mercury in a silastic strain gauge system to assess the effect of pressure step size, on the time course of the rapid volume response (RVR) to occlusion pressure. We also obtained values for hydraulic conductance (Kf), isovolumetric venous pressure (Pvi) and venous pressure (Pv) in thirty‐five studies on the legs of twenty‐three supine control subjects. 2. The initial rapid volume response to small (9.53 +/‐ 0.45 mmHg, mean +/‐ S.E.M.) stepped increases in venous pressure, the rapid volume response, could be described by a single exponential of time constant 15.54 +/‐ 1.14 s. 3. Increasing the size of the pressure step, to 49.8 +/‐ 1.1 mmHg, gave a larger value for the RVR time constant (mean 77.3 +/‐ 11.6 s). 4. We propose that the pressure‐dependent difference in the duration of the rapid volume response, in these two situations, might be due to a vascular smooth muscle‐based mechanism, e.g. the veni‐arteriolar reflex. 5. The mean (+/‐ S.E.M.) values for Kf, Pvi and Pv were 4.27 +/‐ 0.18 (units, ml min‐1 (100 g)‐1 mmHg‐1 x 10(‐3), 21.50 +/‐ 0.81 (units, mmHg) and 9.11 +/‐ 0.94 (units, mmHg), respectively. 6. During simultaneous assessment of these parameters in arms and legs, it was found that they did not differ significantly from one another. 7. We propose that the mercury strain gauge system offers a useful, non‐invasive means of studying the mechanisms governing fluid filtration in human limbs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cai, L., Song, L., Luan, P., Zhang, Q., Zhang, N., Gao, Q., Zhao, D., Zhang, X., Tu, M., Yang, F., et al. (2013) · Scientific Reports · doi:10.1038/srep03048 · Cited by 682
Venous occlusion plethysmography in cardiovascular research: methodology and clinical applications
Wilkinson, I. B., & Webb, D. J. (2001) · British Journal of Clinical Pharmacology · doi:10.1046/j.0306-5251.2001.01495.x · Cited by 355
Christ, F., Gamble, J., Baschnegger, H., & Gartside, I. B. (1997) · The Journal of Physiology · doi:10.1111/j.1469-7793.1997.463bh.x · Cited by 182
“Kf is determined from the relationship between fluid filtration and the applied Pcuff (Gamble et al. 1993).”
BackgroundMethodSelf-citationCocks, M., Shaw, C. S., Shepherd, S. O., Fisher, J. P., Ranasinghe, A., Barker, T. A., & Wagenmakers, A. J. M. (2016) · The Journal of Physiology · doi:10.1113/jphysiol.2014.285254 · Cited by 117
Reduced lymphatic reserve in heart failure with preserved ejection fraction
Rossitto, G., Mary, S., McAllister, C., Neves, K. B., Haddow, L., Rocchiccioli, J. P., Lang, N. N., Murphy, C. L., Touyz, R. M., Petrie, M. C., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.10.022 · Cited by 77
Metadata
- Authors
- Gamble, J., Gartside, I. B., & Christ, F.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1993-05
- Volume
- 464
- Issue
- 1
- Pages
- 407-422
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2168998898
- Cited by
- 135
- References
- 0
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A reassessment of mercury in silastic strain gauge plethysmography for microvascular permeability assessment in man. https://app.cochat.ai/papers/10.1113/jphysiol.1993.sp019642
- The paper
- Gamble, J., Gartside, I. B., & Christ, F. (1993). A reassessment of mercury in silastic strain gauge plethysmography for microvascular permeability assessment in man. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1993.sp019642
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.