Cited by 41Neuroscience of respiration and sleepHeart Rate Variability and Autonomic ControlObstructive Sleep Apnea Research

The DOI matches its Crossref record.

Post-hyperventilation apnoea in conscious humans

Open access
Meah, M S, Gardner, W N·1994·The Journal of Physiology

Abstract

1. In nine normal subjects, analysis was performed of the number, length and location of apnoeic pauses during 20 min of recovery following voluntary overbreathing (VHV). Four different rates of recovery of end‐tidal PCO2 (PET,CO2), studied in randomized order, were induced by overbreathing to 15 or 25 mmHg, each for 3 or 6 min. Subjects breathed mildly hyperoxic gas mixtures (inspired PO2 approximately 250 mmHg) to and fro into an open circuit via a mouthpiece and pneumotachograph. 2. Apnoeic pauses rarely occurred immediately after the end of VHV but gradually increased in number and length. When averaged across all subjects and protocols, the largest pauses occurred 2.0 +/‐ 0.3 min (S.D.; range 1.6‐2.4 min) after the end of VHV. Based on a definition of apnoea as expiratory time greater than 6 s, apnoeas occurred between mean times of 0.8 and 5.6 min after the end of VHV, the end of this period being associated with a mean PET,CO2 value of 36.4 mmHg, which was below the initial mean resting value of 39.8 mmHg. 3. Within this apnoeic period, 80% of experiments produced apnoeas of less than 10 s duration, 61% of between 10 and 20 s duration and 42% of between 20 and 30 s duration. Only one out of nine subjects consistently failed to show apnoeas. 4. The range of lengths of individual apnoeas and the number per minute were independent of the length and level of VHV and were not significantly different between the four protocols. 5. The number and length of apnoeas did not change in repeated runs in each subject. We were not able to confirm previous reports that apnoeas occurred more frequently in subjects familiar with the experiment. 6. These results reconciled previous studies showing either apnoea or hyperpnoea following voluntary overbreathing in conscious humans. They showed an initial period of heightened breathing lasting about a minute with few apnoeas, consistent with ‘after‐discharge’. Beyond that, apnoeas occurred as an ‘all‐or‐nothing’ phenomenon as long as PET,CO2 was on average less than 3.4 mmHg below resting PET,CO2. The occurrence and length of apnoeas was consistent in individual subjects with no evidence of a learning effect.

Overview

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1994.sp020213

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cited by

Sorted by citations

See all 41

Metadata

Authors
Meah, M. S., & Gardner, W. N.
Affiliations
King's College London (GB)
Venue
The Journal of Physiology
Publisher
Wiley
Published
1994-06-15
Volume
477
Issue
3
Pages
527-538
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2121049369
Cited by
41
References
0
Citations by year
2026: 1 · 2023: 1 · 2022: 3 · 2013: 1 · 2012: 1
FWCI
2.48
Type
journal article
Language
en
Open access
Locations
  • The Journal of Physiology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Wellcome Trust
  • National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR-17803)
  • Eunice Kennedy Shriver National Institute of Child Health and Human Development (HD-12629)
Topics
  • Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Neuroscience of respiration and sleep
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
Keywords
hyperpnoea, end-tidal carbon dioxide, hyperoxia, afterdischarge, hypercapnia, respiratory control
MeSH terms
Adult, Apnea, Female, Humans, Hyperventilation, Male, Respiration, Time Factors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review