Time‐varying enhancement of human cortical excitability mediated by cutaneous inputs during precision grip.
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
1. We have investigated the afferent neurogram, muscular activity and mechanical responses while subjects restrained, with a precision grip, an object subjected to pulling loads directed away from the hand. At unpredictable times ‘ramp‐and‐hold’ loads of 1 N were delivered at a rate of ca 80 N s‐1. The load ramp produced a sharp increase in multiunit activity recorded from cutaneous afferents of the median nerve. The first response in the EMG of distal hand muscles commenced at 51 +/‐ 2.4 ms (mean +/‐ S.D.); a further steep increase in activity began about 20 ms later, and this was associated with a marked augmentation of the grip force increase. 2. In four subjects, transcranial magnetic stimulation (TMS) was delivered to the contralateral motor cortex in 1000 out of a total of 1500 loading trials. The time of the stimulus was randomly selected to occur either at one of nine defined points (separated by 20 ms) before and after the computer command triggering the load force increase, or during steady periods of grip. 3. In most hand and arm muscles, there was a powerful facilitation of the short‐latency EMG responses evoked by TMS delivered 40‐140 ms after the load force command. The amplitudes of the largest responses (TMS delivered at 80‐100 ms) were 850% higher on average than those observed when subjects gripped the unloaded object or when they restrained the statically loaded object. This large modulation was only obtained with stimulus intensities that were subthreshold in the relaxed subject. 4. The modulation was not simply a reflection of the time‐varying level of motoneuronal activity during the loading trial. In most muscles, changes in the amplitude of the TMS‐evoked responses were disproportionately larger than the corresponding modulation of the background EMG activity. At its maximum, the modulation in the TMS‐evoked response was nearly 300% larger. Furthermore, the strength of the TMS‐evoked responses did not strictly co‐vary with amplitude of background EMG, i.e. inverse relationships were seen. 5. Since motor responses to the loading of the object depend on cutaneous afferent input from the gripping digits, the results demonstrate an interaction between the effects of these inputs and those of TMS. A possible site of this interaction is the primary motor cortex; the strong modulation of the responses to TMS could reflect variation in the excitability of cortical neurons mediated by the cutaneous afferent input. However, such excitability changes lagged the predicted onset of cortical excitation in a manner suggesting that the earliest 20 ms of the subjects’ EMG responses to the load increase are subcortical in origin. In contrast, the results are consistent with a cortical mediation of the subsequent powerful boosting of the EMG responses associated with the robust grip force response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Johansson, R. S., & Westling, G. (1987) · Experimental Brain Research · doi:10.1007/bf00236210 · Cited by 865
Self-citationTactile sensory coding in the glabrous skin of the human hand
Johansson, R. S., & Vallbo, Å. B. (1983) · Trends in Neurosciences · doi:10.1016/0166-2236(83)90011-5 · Cited by 680
Self-citationJohansson, R. S., Riso, R., Häger, C., & Bäckström, L. (1992) · Experimental Brain Research · doi:10.1007/bf00229015 · Cited by 274
Self-citation
Cited by
Descending Pathways in Motor Control
Lemon, R. N. (2008) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.31.060407.125547 · Cited by 1,599
“CM cells may also be involved in the generation of transcortical reflexes (Cheney & Fetz 1984), which could underpin fast and powerful responses to peripheral perturbations ( Johansson et al. 1994).”
BackgroundSelf-citationFirst spikes in ensembles of human tactile afferents code complex spatial fingertip events
Johansson, R. S., & Birznieks, I. (2004) · Nature Neuroscience · doi:10.1038/nn1177 · Cited by 638
Self-citationState of the art: Physiology of transcranial motor cortex stimulation
Lazzaro, V. D., Ziemann, U., & Lemon, R. N. (2008) · Brain Stimulation · doi:10.1016/j.brs.2008.07.004 · Cited by 359
Self-citationSensory Control of Dexterous Manipulation in Humans
Johansson, R. S. (1996) · Hand and Brain · doi:10.1016/b978-012759440-8/50025-6 · Cited by 255
Self-citationCorticospinal control during reach, grasp, and precision lift in man
Lemon, R., Johansson, R., & Westling, G. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-09-06145.1995 · Cited by 239
“observed in an earlier study in which the subject's task was to restrain an object held in a precision grip while it was subjected to unpredictable loads ( Johansson et al., 1994 ).”
BackgroundMethodResultInfluentialSelf-citation
Metadata
- Authors
- Johansson, R. S., Lemon, R. N., & Westling, G.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1994-12-15
- Volume
- 481
- Issue
- 3
- Pages
- 761-775
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1972937204
- Cited by
- 83
- References
- 3
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.