Response of C fibre nociceptors in the anaesthetized monkey to heat stimuli: estimates of receptor depth and threshold.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
1. Responses to ramped or stepped temperature stimuli were obtained from fifty‐three cutaneous C fibre mechano‐heat nociceptors (CMHs) in the hairy skin of the pentobarbitone‐morphine anaesthetized monkey. A three‐layer heat transfer model was developed to describe the temperature distribution within the skin and to estimate receptor depth and heat threshold. 2. Surface heat threshold, defined as the surface temperature when the first action potential occurs, increased as: (a) the rate of temperature rise for the ramped stimuli increased from 0.095 to 5.8 degrees C s‐1; (b) the duration of stepped heat stimuli decreased from 30 to 1 s; and (c) the base temperature of stepped heat stimuli decreased from 38 to 35 degrees C. These results suggest that the heat threshold for CMHs is determined by the temperature at the depth of the receptor. 3. Receptor depth estimates from responses to ramped stimuli ranged from 20 to 570 microns with a mean of 201 microns. The estimated mean receptor heat threshold was 40.4 +/‐ 2.2 degrees C (+/‐ S.D.). No correlation was observed between depth and thermal or mechanical threshold. The average receptor depth and threshold, estimated from the responses to stepped heat stimuli, were 150 microns and 40.2 degrees C, respectively. 4. We conclude that: (a) the receptor endings of CMHs occur in the epidermis and dermis; (b) temperature at the level of the receptor determines threshold; (c) temperature at the receptor ending is much lower than skin surface temperature at threshold; and (d) the tight distribution of receptor heat thresholds suggests a uniform transducer mechanism for heat in CMHs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The pattern of cutaneous innervation of the human hand
Miller, M. R., Ralston, H. J., & Kasahara, M. (1958) · American Journal of Anatomy · doi:10.1002/aja.1001020203 · Cited by 113
Cited by
Rácz, I., & Zimmer, A. (2006) · Standards of Mouse Model Phenotyping · doi:10.1002/9783527611942.ch9 · Cited by 1,659
Le Bars, D., Gozariu, M., & Cadden, S. W. (2001) · Pharmacological Reviews · doi:10.1016/s0031-6997(24)01514-x · Cited by 1,459
ThermoTRP channels and beyond: mechanisms of temperature sensation
Patapoutian, A., Peier, A. M., Story, G. M., & Viswanath, V. (2003) · Nature Reviews Neuroscience · doi:10.1038/nrn1141 · Cited by 873
Tominaga, M., & Caterina, M. J. (2004) · Journal of Neurobiology · doi:10.1002/neu.20079 · Cited by 520
Clinical usefulness of laser-evoked potentials
Treede, R.-D., Lorenz, J., & Baumgärtner, U. (2003) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2003.10.009 · Cited by 389
Self-citation
Metadata
- Authors
- Tillman, D. B., Treede, R. D., Meyer, R. A., & Campbell, J. N.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1995-06-15
- Volume
- 485
- Issue
- 3
- Pages
- 753-765
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2015779596
- Cited by
- 133
- References
- 1
- FWCI
- 1.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.