Postextrasystolic regulation patterns of blood pressure and heart rate in patients with idiopathic dilated cardiomyopathy
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Assessment of fluctuations in heart rate (HR) following a premature ventricular complex (PVC) is valuable for identifying patients at high risk of sudden cardiac death. We hypothesised that postextrasystolic potentiation is the main determinant of the regulation patterns of blood pressure (BP) and HR following a PVC. Twelve patients with idiopathic dilated cardiomyopathy (IDC) and 13 control subjects with single PVCs (comparable coupling intervals) were investigated. Non‐invasive finger arterial BP and ECGs were analysed. Regulation patterns following a single PVC were quantified using the indices postextrasystolic amplitude potentiation (PEAP) and maximum turbulence slope of five consecutive mean BP values (MBP‐TS), and compared with the HR turbulence parameters turbulence slope (HR‐TS) and turbulence onset (HR‐TO). PEAP was significantly higher in IDC patients compared to controls (48.7 ± 32.6 vs. 9.8 ± 5.4 %, P < 0.01), whereas MBP‐TS was lower (0.97 ± 0.60 vs. 2.07 ± 1.04 mmHg BBI−1 (BBI, beat‐to‐beat interval), P < 0.05), as was HR‐TS (8.46 ± 7.90 vs. 30.73 ± 22.90 ms BBI−1, P < 0.01). HR‐TO was significantly higher in IDC patients (−0.56 ± 2.19 vs.−5.52 ± 4.13 %, P < 0.01). In addition, the regulation patterns of BP and HR following a single PVC differed significantly between IDC patients and controls. Specifically, we observed pronounced PEAPs in IDC patients. The baroreflex response initiated by the low pressure amplitude of the PVC was suppressed in IDC patients due to the augmented potentiation of the first postextrasystolic blood pressure. Furthermore, IDC patients displayed impressive postextrasystolic pulsus alternans phenomena, whereas healthy subjects exhibited a typical baroreflex pattern. The pulsus alternans phenomenon seems to be triggered by a PVC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schmidt, G., Malik, M., Barthel, P., Schneider, R., Ulm, K., Rolnitzky, L., Camm, A. J., Bigger, J. T., & Schömig, A. (1999) · The Lancet · doi:10.1016/s0140-6736(98)08428-1 · Cited by 716
Cited by
Heart Rate Turbulence: Standards of Measurement, Physiological Interpretation, and Clinical Use
Bauer, A., Malik, M., Schmidt, G., Barthel, P., Bonnemeier, H., Cygankiewicz, I., Guzik, P., Lombardi, F., Müller, A., Oto, A., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.041 · Cited by 462
“Compared with healthy control patients, HRT indexes are also significantly depressed in patients with congestive heart failure (43) as well as in the presence of structural heart disease with preserved left ventricular function (37,44).”
Cygankiewicz, I., Zareba, W., Vazquez, R., Vallverdu, M., Gonzalez-Juanatey, J. R., Valdes, M., Almendral, J., Cinca, J., Caminal, P., & de Luna, A. B. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.017 · Cited by 113
Post-extrasystolic Blood Pressure Potentiation as a Risk Predictor in Cardiac Patients
Steger, A., 1st Medical Clinic and Policlinic, K. R. D. I., Sinnecker, D., 1st Medical Clinic and Policlinic, K. R. D. I., Barthel, P., 1st Medical Clinic and Policlinic, K. R. D. I., Müller, A., 1st Medical Clinic and Policlinic, K. R. D. I., Gebhardt, J., 1st Medical Clinic and Policlinic, K. R. D. I., et al. (2016) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2016.14.2 · Cited by 8
Metadata
- Authors
- Voss, A., Baier, V., Schumann, A., Hasart, A., Reinsperger, F., Schirdewan, A., Osterziel, K., & Leder, U.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 2002-01
- Volume
- 538
- Issue
- 1
- Pages
- 271-278
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2026163631
- Cited by
- 53
- References
- 1
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.