Cited by 41Corneal surgery and disordersOcular Surface and Contact LensCorneal Surgery and Treatments

Transparency of the bovine corneal stroma at physiological hydration and its dependence on concentration of the ambient anion

Open access
Kostyuk, Oksana, Nalovina, Oksana, Mubard, Turki M., Regini, Justyn W., Meek, Keith M., Quantock, Andrew J., Elliott, Gerald F., Hodson, Stuart A.·2002·The Journal of Physiology

Abstract

De‐epithelialised and de‐endothelialised bovine corneal stromas with a hydration of 3.2 equilibrated at 154 m m NaCl and buffered at pH 7.4 had their optical density (400–750 nm) measured. Stromas equilibrated against 10, 20, 30, 50 or 100 m m NaCl made isotonic to 154 m m NaCl by supplementing with sorbitol were progressively more transparent as NaCl increased. Hypertonic equilibration against 300, 600 or 1000 m m NaCl resulted in a progressive loss of transparency compared with 154 m m NaCl. Light scattering as a function of wavelength fitted a λ −3 function well for 10, 30, 50, 100 and 154 m m NaCl preparations between 450 and 650 nm, but not at higher wavelengths. However, hypertonic 300, 600 and 1000 m m NaCl preparations showed a λ −2 dependence in the 450–750 nm range. Experiments with 154 m m NaCl and either 0 or 300 m m sorbitol suggested that the changes in light scattering in hypertonic preparations are unlikely to be caused by osmotic alterations to the stromal keratocytes. Psychophysical studies of the optical transmission function of preparations indicated that corneal stromas dialysed against 154 m m NaCl had usable optical properties, but preparations dialysed against 10 m m NaCl were effectively unable to transmit an image. The results are related to the known increase of fixed negative charge in the corneal matrix when chloride ions are adsorbed onto the matrix. It is suggested that the ordering force between corneal collagen fibrils, generated in part by anion binding, may be crucial to the physiological functioning of the visual system.

Integrity signals

Registry

Crossref · 10.1113/jphysiol.2002.021527

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The corneal stroma contains specialised glycoproteins and ions that play an important role in organising the collagen fibrils in order to maintain transparency.

    “It also contains specialised glycoproteins (Labat-Robert and Robert, 2012, Wall et al., 1988, Cooper et al., 2006) and, of course, ions that play an important role in organising the collagen fibrils in order to maintain transparency (Kostyuk et al., 2002, Regini et al., 2004).”

    From Corneal structure and transparency (2015) · cites this paper as Kostyuk et al., 2002

  • For quantitative measurement of corneal light transmission, it is important to ensure that the cornea is maintained under tension, because releasing intraocular pressure leads to undulations of the lamellae and increased light scatter.

    “It is also important to ensure that the cornea is maintained under tension, as it is usually necessary to remove the cornea from the globe to make the transmission measurement. Otherwise, when the tension due to the intraocular pressure is released, it seems that the resulting undulations of the lamellae lead to increased light scatter (McCally and Farrell, 1977, Kostyuk et al., 2002).”

    From Corneal structure and transparency (2015) · cites this paper as Kostyuk et al., 2002

Cited by

Sorted by citations

Authors
Kostyuk, O., Nalovina, O., Mubard, T. M., Regini, J. W., Meek, K. M., Quantock, A. J., Elliott, G. F., & Hodson, S. A.
Affiliations
Cardiff University (GB)
Corresponding author
Hodson, Stuart A.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2002-09
Volume
543
Issue
2
Pages
633-642
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2171636338
Cited by
41
References
0
Citations by year
2020: 1 · 2019: 4 · 2017: 1 · 2016: 1 · 2015: 5 · 2014: 2 · 2013: 3 · 2012: 4
FWCI
1.71
Type
journal article
Language
en
Open access
Locations
  • The Journal of Physiology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • ORCA Online Research @Cardiff (Cardiff University) (submittedVersion)
Funders
Engineering and Physical Sciences Research Council
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Ocular Surface and Contact Lens
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal Surgery and Treatments
Keywords
corneal stroma, optical transparency, light scattering, corneal hydration, NaCl concentration, anion binding, chloride, sorbitol, keratocytes, optical transmission, negative fixed charge, bovine cornea
MeSH terms
Animals, Anions, Cattle, Corneal Stroma, Isotonic Solutions, Light, Osmotic Pressure, Saline Solution, Hypertonic, Scattering, Radiation, Water, Optics and Photonics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review