Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 233

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Acute dopamine/noradrenaline reuptake inhibition enhances human exercise performance in warm, but not temperate conditions

Watson, Phillip, Hasegawa, Hiroshi, Roelands, Bart, Piacentini, Maria Francesca, Looverie, Roel, Meeusen, Romain·2005·The Journal of Physiology

Abstract

Nine healthy endurance‐trained males were recruited to examine the effect of a dual dopamine/noradrenaline reuptake inhibitor on performance, thermoregulation and the hormonal responses to exercise. Subjects performed four trials, ingesting either a placebo (pla) or 2 × 300 mg bupropion (bup), prior to exercise in temperate (18°C) or warm (30°C) conditions. Trials consisted of 60 min cycle exercise at 55%Wmax immediately followed by a time trial (TT). TT performance in the heat was significantly improved by bupropion (pla: 39.8 ± 3.9 min, bup: 36.4 ± 5.7 min; P= 0.046), but no difference between treatments was apparent in temperate conditions (pla: 30.6 ± 2.2 min, bup: 30.6 ± 1.9 min; P= 0.954). While TT power output was consistently lower in the heat when compared to temperate conditions, this decrement was attenuated by bupropion. At the end of the TT in the heat, both core temperature (pla 39.7 ± 0.3°C, bup 40.0 ± 0.3°C; P= 0.017) and HR (pla 178 ± 7 beats min−1, bup 183 ± 12 beats min−1; P= 0.039), were higher in the bupropion trial than in the placebo. Circulating pituitary and adrenal hormone concentrations increased throughout exercise in all trials. Circulating serum prolactin was elevated above temperate levels during exercise in a warm environment (P < 0.001). These data indicate that performance in warm conditions is enhanced by acute administration of a dual dopamine/noradrenaline reuptake inhibitor. No such effect was apparent under temperate conditions. It appears that bupropion enabled subjects to maintain a greater TT power output in the heat with the same perception of effort and thermal stress reported during the placebo trial, despite the attainment of a higher core temperature.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.2004.079202

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 233

Metadata

Authors
Watson, P., Hasegawa, H., Roelands, B., Piacentini, M. F., Looverie, R., & Meeusen, R.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2005-06-15
Volume
565
Issue
3
Pages
873-883
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2124951891
Cited by
233
References
2
FWCI
4.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.