CoChat

Effect of repetitive hypoxic apnoeas on baroreflex function in humans

Open access
Monahan, Kevin D., Leuenberger, Urs A., Ray, Chester A. · 2006 · The Journal of Physiology
Cited by 69

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Baroreflex function is impaired in patients with obstructive sleep apnoea. We tested the hypothesis that short‐term exposure to repetitive hypoxic apnoeas (RHA) produces prolonged impairment in baroreflex function. Baroreflex function was determined using the modified Oxford technique in 14 subjects (26 ± 1 years). Baroreflex sensitivity (BRS) was quantified from the R‐R interval–systolic blood pressure (BP; cardiovagal BRS), heart rate–systolic BP (HR BRS) and muscle sympathetic nerve activity (MSNA)–diastolic BP (sympathetic BRS) relations. RHA involved subjects performing repetitive end‐expiratory apnoeas (20 s) every minute for 30 min during intermittent hypoxia to accentuate oxygen desaturation. After RHA, BP and MSNA at rest were elevated. BRS was measured ∼7 (Post 1), ∼30 (Post 2) and ∼50 min (Post 3) after RHA to provide insight into the temporal pattern of responses. Cardiovagal BRS (16.8 ± 1.3, 16.5 ± 1.6, 17.6 ± 2.0 and 17.4 ± 1.5 ms mmHg−1 for Pre, Post 1, Post 2 and Post 3, respectively), HR BRS (−1.1 ± 0.1, −1.1 ± 0.1, −1.3 ± 0.1 and −1.4 ± 0.1 beats min−1 mmHg−1) and sympathetic BRS (−4.5 ± 0.6, −4.4 ± 0.7, −3.7 ± 0.5 and −4.7 ± 1.0 arbitrary units (au) beat−1 mmHg−1) were unchanged by RHA. In contrast, the operating points of the baroreflexes were shifted rightward (to higher levels of BP) and upward (to higher levels of heart rate and MSNA) after RHA (P < 0.05). Time control studies performed in five additional subjects showed no change in any of the measured variables over time. Collectively, these data indicate that short‐term exposure to RHA shifts (‘resets’) the baroreflex stimulus–response curve to higher levels of BP without influencing BRS for extended periods of time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.2006.108977

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 69

Metadata

Authors
Monahan, K. D., Leuenberger, U. A., & Ray, C. A.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2006-07-06
Volume
574
Issue
2
Pages
605-613
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1491791846
Cited by
69
References
5
FWCI
3.06
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of repetitive hypoxic apnoeas on baroreflex function in humans. https://app.cochat.ai/papers/10.1113/jphysiol.2006.108977
The paper
Monahan, K. D., Leuenberger, U. A., & Ray, C. A. (2006). Effect of repetitive hypoxic apnoeas on baroreflex function in humans. The Journal of Physiology. https://doi.org/10.1113/jphysiol.2006.108977

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.