The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Brain–computer interfaces as new brain output pathways
Open accessAbstract
Brain–computer interfaces (BCIs) can provide non‐muscular communication and control for people with severe motor disabilities. Current BCIs use a variety of invasive and non‐invasive methods to record brain signals and a variety of signal processing methods. Whatever the recording and processing methods used, BCI performance (e.g. the ability of a BCI to control movement of a computer cursor) is highly variable and, by the standards applied to neuromuscular control, could be described as ataxic. In an effort to understand this imperfection, this paper discusses the relevance of two principles that underlie the brain's normal motor outputs. The first principle is that motor outputs are normally produced by the combined activity of many CNS areas, from the cortex to the spinal cord. Together, these areas produce appropriate control of the spinal motoneurons that activate muscles. The second principle is that the acquisition and life‐long preservation of motor skills depends on continual adaptive plasticity throughout the CNS. This plasticity optimizes the control of spinal motoneurons. In the light of these two principles, a BCI may be viewed as a system that changes the outcome of CNS activity from control of spinal motoneurons to, instead, control of the cortical (or other) area whose signals are used by the BCI to determine the user's intent. In essence, a BCI attempts to assign to cortical neurons the role normally performed by spinal motoneurons. Thus, a BCI requires that the many CNS areas involved in producing normal motor actions change their roles so as to optimize the control of cortical neurons rather than spinal motoneurons. The disconcerting variability of BCI performance may stem in large part from the challenge presented by the need for this unnatural adaptation. This difficulty might be reduced, and BCI development might thereby benefit, by adopting a ‘goal‐selection’ rather than a ‘process‐ control’ strategy. In ‘process control’, a BCI manages all the intricate high‐speed interactions involved in movement. In ‘goal selection’, by contrast, the BCI simply communicates the user's goal to software that handles the high–speed interactions needed to achieve the goal. Not only is ‘goal selection’ less demanding, but also, by delegating lower‐level aspects of motor control to another structure (rather than requiring that the cortex do everything), it more closely resembles the distributed operation characteristic of normal motor control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Self-citationNeuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Cognitive Control Signals for Neural Prosthetics
Musallam, S., Corneil, B. D., Greger, B., Scherberger, H., & Andersen, R. A. (2004) · Science · doi:10.1126/science.1097938 · Cited by 663
Cited by
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
Single-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138
Introduction to machine learning for brain imaging
Lemm, S., Blankertz, B., Dickhaus, T., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.004 · Cited by 630
Think to Move: a Neuromagnetic Brain-Computer Interface (BCI) System for Chronic Stroke
Buch, E., Weber, C., Cohen, L. G., Braun, C., Dimyan, M. A., Ard, T., Mellinger, J., Caria, A., Soekadar, S., Fourkas, A., et al. (2008) · Stroke · doi:10.1161/strokeaha.107.505313 · Cited by 600
Fully Implanted Brain–Computer Interface in a Locked-In Patient with ALS
Vansteensel, M. J., Pels, E. G. M., Bleichner, M. G., Branco, M. P., Denison, T., Freudenburg, Z. V., Gosselaar, P., Leinders, S., Ottens, T. H., Van Den Boom, M. A., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1608085 · Cited by 578
Metadata
- Authors
- Wolpaw, J. R.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 2007-03-14
- Volume
- 579
- Issue
- 3
- Pages
- 613-619
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2158006723
- Cited by
- 348
- References
- 4
- FWCI
- 11.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Brain–computer interfaces as new brain output pathways. https://app.cochat.ai/papers/10.1113/jphysiol.2006.125948
- The paper
- Wolpaw, J. R. (2007). Brain–computer interfaces as new brain output pathways. The Journal of Physiology. https://doi.org/10.1113/jphysiol.2006.125948
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.