The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Human lymphatic pumping measured in healthy and lymphoedematous arms by lymphatic congestion lymphoscintigraphy
Open accessAbstract
Axillary surgery for breast cancer partially obstructs lymph outflow from the arm, chronically raising the lymphatic smooth muscle afterload. This may lead to pump failure, as in hypertensive cardiac failure, and could explain features of breast cancer treatment‐related lymphoedema (BCRL) such as its delayed onset. A new method was developed to measure human lymphatic contractility non‐invasively and test the hypothesis of contractile impairment. 99m Tc‐human IgG (Tc‐HIG), injected into the hand dermis, drained into the arm lymphatic system which was imaged using a gamma‐camera. Lymph transit time from hand to axilla, ttransit, was 9.6 ± 7.2 min (mean ±s.d.) (velocity 8.9 cm min−1) in seven normal subjects. To assess lymphatic contractility, a sphygmomanometer cuff around the upper arm was inflated to 60 mmHg (Pcuff) before 99m Tc‐HIG injection and maintained for >> ttransit. When Pcuff exceeded the maximum pressure generated by the lymphatic pump (Ppump), radiolabelled lymph was held up at the distal cuff border. Pcuff was then lowered in 10 mmHg steps until 99m Tc‐HIG began to flow under the cuff to the axilla, indicating Ppump≥Pcuff. In 16 normal subjects Ppump was 39 ± 14 mmHg. Ppump was 38% lower in 16 women with BCRL, namely 24 ± 19 mmHg (P= 0.014, Student's unpaired t test), and correlated negatively with the degree of swelling (12–56%). Blood radiolabel accumulation proved an unreliable measure of lymphatic pump function. Lymphatic congestion lymphoscintigraphy thus provided a quantitative measure of human lymphatic contractility without surgical cut‐down, and the results supported the hypothesis of lymphatic pump failure in BCRL.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intrinsic contractility of prenodal lymph vessels and lymph flow in human leg
Olszewski, W. L., & Engeset, A. (1980) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1980.239.6.h775 · Cited by 201
Cited by
Wiig, H., & Swartz, M. A. (2012) · Physiological Reviews · doi:10.1152/physrev.00037.2011 · Cited by 722
Lymphatic pumping: mechanics, mechanisms and malfunction
Scallan, J. P., Zawieja, S. D., Castorena‐Gonzalez, J. A., & Davis, M. J. (2016) · The Journal of Physiology · doi:10.1113/jp272088 · Cited by 424
Lymphatic Vessel Network Structure and Physiology
Breslin, J. W., Yang, Y., Scallan, J. P., Sweat, R. S., Adderley, S. P., & Murfee, W. L. (2018) · Comprehensive Physiology · doi:10.1002/cphy.c180015 · Cited by 341
Subcutaneous Absorption of Biotherapeutics: Knowns and Unknowns
Richter, W. F., & Jacobsen, B. (2014) · Drug Metabolism and Disposition · doi:10.1124/dmd.114.059238 · Cited by 235
Zheng, Y., Tesar, D. B., Benincosa, L., Birnböck, H., Boswell, C. A., Bumbaca, D., Cowan, K. J., Danilenko, D. M., Daugherty, A. L., Fielder, P. J., et al. (2012) · mAbs · doi:10.4161/mabs.4.2.19387 · Cited by 149
Metadata
- Authors
- Modi, S., Stanton, A. W. B., Svensson, W. E., Peters, A. M., Mortimer, P. S., & Levick, J. R.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 2007-08
- Volume
- 583
- Issue
- 1
- Pages
- 271-285
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1939019704
- Cited by
- 167
- References
- 1
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Human lymphatic pumping measured in healthy and lymphoedematous arms by lymphatic congestion lymphoscintigraphy. https://app.cochat.ai/papers/10.1113/jphysiol.2007.130401
- The paper
- Modi, S., Stanton, A. W. B., Svensson, W. E., Peters, A. M., Mortimer, P. S., & Levick, J. R. (2007). Human lymphatic pumping measured in healthy and lymphoedematous arms by lymphatic congestion lymphoscintigraphy. The Journal of Physiology. https://doi.org/10.1113/jphysiol.2007.130401
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.