The DOI matches its Crossref record.
Human cutaneous reactive hyperaemia: role of BKCachannels and sensory nerves
Open accessAbstract
Reactive hyperaemia is the increase in blood flow following arterial occlusion. The exact mechanisms mediating this response in skin are not fully understood. The purpose of this study was to investigate the individual and combined contributions of (1) sensory nerves and large‐conductance calcium activated potassium (BK Ca) channels, and (2) nitric oxide (NO) and prostanoids to cutaneous reactive hyperaemia. Laser‐Doppler flowmetry was used to measure skin blood flow in a total of 18 subjects. Peak blood flow (BF) was defined as the highest blood flow value after release of the pressure cuff. Total hyperaemic response was calculated by taking the area under the curve (AUC) of the hyperaemic response minus baseline. Infusates were perfused through forearm skin using microdialysis in four sites. In the sensory nerve/BK Ca protocol: (1) EMLA®cream (EMLA, applied topically to skin surface), (2) tetraethylammonium (TEA), (3) EMLA®+ TEA (Combo), and (4) Ringer solution (Control). In the prostanoid/NO protocol: (1) ketorolac (Keto), (2)NG‐nitro‐l‐arginine methyl ester (l‐NAME), (3) Keto +l‐NAME (Combo), and (4) Ringer solution (Control). CVC was calculated as flux/mean arterial pressure and normalized to maximal flow. Hyperaemic responses in Control (1389 ± 794%CVC max s) were significantly greater compared to TEA, EMLA and Combo sites (TEA, 630 ± 512,P= 0.003; EMLA, 421 ± 216,P< 0.001; Combo, 201 ± 200,P< 0.001%CVC max s). Furthermore, AUC in Combo (Keto +l‐NAME) site was significantly greater than Control (4109 ± 2777 versus 1295 ± 368%CVC max s). These data suggest (1) sensory nerves and BK Ca channels play major roles in the EDHF component of reactive hyperaemia and appear to work partly independent of each other, and (2) the COX pathway does not appear to have a vasodilatory role in cutaneous reactive hyperaemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Non‐invasive Assessment of Skin Microvascular Function in Humans: An Insight Into Methods
ROUSTIT, M., & CRACOWSKI, J. (2012) · Microcirculation · doi:10.1111/j.1549-8719.2011.00129.x · Cited by 373
Assessment of endothelial and neurovascular function in human skin microcirculation
Roustit, M., & Cracowski, J.-L. (2013) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2013.05.007 · Cited by 353
Choi, P. J., Brunt, V. E., Fujii, N., & Minson, C. T. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01397.2013 · Cited by 123
Self-citationde Moraes, R., Van Bavel, D., de Moraes, B. S., & Tibiriçá, E. (2014) · Nutrition Journal · doi:10.1186/1475-2891-13-115 · Cited by 35
Metadata
- Authors
- Lorenzo, S., & Minson, C. T.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 2007-11-14
- Volume
- 585
- Issue
- 1
- Pages
- 295-303
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1546150314
- Cited by
- 182
- References
- 0
- FWCI
- 1.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Human cutaneous reactive hyperaemia: role of BKCachannels and sensory nerves. https://app.cochat.ai/papers/10.1113/jphysiol.2007.143867
- The paper
- Lorenzo, S., & Minson, C. T. (2007). Human cutaneous reactive hyperaemia: role of BKCachannels and sensory nerves. The Journal of Physiology. https://doi.org/10.1113/jphysiol.2007.143867
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.