The DOI matches its Crossref record.
Substrate Deformation Levels Associated With Routine Physical Activity Are Less Stimulatory to Bone Cells Relative to Loading-Induced Oscillatory Fluid Flow
Abstract
Although it is well accepted that bone tissue metabolism is regulated by external mechanical loads, it remains unclear to what load-induced physical signals bone cells respond. In this study, a novel computer-controlled stretch device and parallel plate flow chamber were employed to investigate cytosolic calcium Ca2+i mobilization in response to a range of dynamic substrate strain levels (0.1–10 percent, 1 Hz) and oscillating fluid flow (2 N/m2, 1 Hz). In addition, we quantified the effect of dynamic substrate strain and oscillating fluid flow on the expression of mRNA for the bone matrix protein osteopontin (OPN). Our data demonstrate that continuum strain levels observed for routine physical activities (<0.5 percent) do not induce Ca2+i responses in osteoblastic cells in vitro. However, there was a significant increase in the number of responding cells at larger strain levels. Moreover, we found no change in osteopontin mRNA level in response to 0.5 percent strain at 1 Hz. In contrast, oscillating fluid flow predicted to occur in the lacunar–canalicular system due to routine physical activities (2 N/m2, 1 Hz) caused significant increases in both Ca2+i and OPN mRNA. These data suggest that, relative to fluid flow, substrate deformation may play less of a role in bone cell mechanotransduction associated with bone adaptation to routine loads. [S0148-0731(00)01204-8]
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Feng, X., & McDonald, J. M. (2011) · Annual Review of Pathology: Mechanisms of Disease · doi:10.1146/annurev-pathol-011110-130203 · Cited by 1,272
Mechanosensation and transduction in osteocytes
Klein-Nulend, J., Bakker, A. D., Bacabac, R. G., Vatsa, A., & Weinbaum, S. (2013) · Bone · doi:10.1016/j.bone.2012.10.013 · Cited by 528
Osteocytes: master orchestrators of bone
Schaffler, M. B., Cheung, W.-Y., Majeska, R., & Kennedy, O. (2014) · Calcified Tissue International · doi:10.1007/s00223-013-9790-y · Cited by 514
Mechanical Strain and Bone Cell Function: A Review
Ehrlich, P. J., & Lanyon, L. E. (2002) · Osteoporosis International · doi:10.1007/s001980200095 · Cited by 512
Boning up on Wolff's Law: Mechanical regulation of the cells that make and maintain bone
Chen, J.-H., Liu, C., You, L., & Simmons, C. A. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.09.016 · Cited by 422
Metadata
- Authors
- You, J., Yellowley, C. E., Donahue, H. J., Zhang, Y., Chen, Q., & Jacobs, C. R.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2000-03-22
- Volume
- 122
- Issue
- 4
- Pages
- 387-393
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2044691550
- Cited by
- 357
- References
- 0
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Substrate Deformation Levels Associated With Routine Physical Activity Are Less Stimulatory to Bone Cells Relative to Loading-Induced Oscillatory Fluid Flow. https://app.cochat.ai/papers/10.1115/1.1287161
- The paper
- You, J., Yellowley, C. E., Donahue, H. J., Zhang, Y., Chen, Q., & Jacobs, C. R. (2000). Substrate Deformation Levels Associated With Routine Physical Activity Are Less Stimulatory to Bone Cells Relative to Loading-Induced Oscillatory Fluid Flow. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.1287161
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.