A generalized solder joint fatigue life model for surface mount packages was previously published in [1,2]. The model is based on correlation to measured crack growth data on BGA joints during thermal cycling. It was subsequently discovered by Anderson et al. that the ANSYS™1 5.2 finite element code used in the model had an error in its method for calculating plastic work [3]. It was shown that significant error in life prediction could result by using a recent version of the code where the bug has been fixed. The error comes about since the original crack growth constants were derived based on plastic work calculations that had the bug. In this paper, crack initiation and growth constants are recalculated using ANSYS™ 5.6. In addition, several other model related issues are explored with respect to the crack growth correlations. For example, 3D slice models were compared to quarter symmetry models. Anand’s constitutive model was compared with Darveaux’s constitutive model. It was shown that the crack growth rate dependence on strain energy density always had an exponent of 1.10+/−0.15. This is in the range of the original correlation. The model was applied to several data sets of tape-based and laminate-based BGAs. The accuracy of absolute predictions is mostly within +/−2X. The accuracy of relative predictions is within +/−25%. However, the accuracy of absolute predictions could be off by a factor of 7 in the worst case, if the analyst uses a modeling procedure that is not consistent with that used for the crack growth correlation. The key to good accuracy is to maintain consistency in the modeling procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of simulation methodology on solder joint crack growth correlation
Darveaux, R. (2002) · 2000 Proceedings. 50th Electronic Components and Technology Conference (Cat. No.00CH37070) · doi:10.1109/ectc.2000.853299 · Cited by 545
Self-citationReliability of Copper Baseplate High Current Power Modules
Fusaro, J. M., & Darveaux, R. (1996) · The International journal of microcircuits and electronic packaging · Cited by 20
Self-citation
Cited by
Ageing and Failure Modes of IGBT Modules in High-Temperature Power Cycling
Smet, V., Forest, F., Huselstein, J.-J., Richardeau, F., Khatir, Z., Lefebvre, S., & Berkani, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2114313 · Cited by 620
Metadata
- Authors
- Darveaux, R.
- Venue
- Journal of Electronic Packaging
- Publisher
- ASME International
- Published
- 2002-07-26
- Volume
- 124
- Issue
- 3
- Pages
- 147-154
- ISSN
- 1043-7398 (ISSN-L)
- 1528-9044
- OpenAlex
- W1981710768
- Cited by
- 303
- References
- 2
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.