The DOI matches its Crossref record.
Heat Transfer Mechanisms During Flow Boiling in Microchannels
Abstract
The forces due to surface tension and momentum change during evaporation, in conjunction with the forces due to viscous shear and inertia, govern the two-phase flow patterns and the heat transfer characteristics during flow boiling in microchannels. These forces are analyzed in this paper, and two new nondimensional groups, K1 and K2, relevant to flow boiling phenomenon are derived. These groups are able to represent some of the key flow boiling characteristics, including the CHF. In addition, a mechanistic description of the flow boiling phenomenon is presented. The small hydraulic dimensions of microchannel flow passages present a large frictional pressure drop in single-phase and two-phase flows. The small hydraulic diameter also leads to low Reynolds numbers, in the range 100–1000, or even lower for smaller diameter channels. Such low Reynolds numbers are rarely employed during flow boiling in conventional channels. In these low Reynolds number flows, nucleate boiling systematically emerges as the dominant mode of heat transfer. The high degree of wall superheat required to initiate nucleation in microchannels leads to rapid evaporation and flow instabilities, often resulting in flow reversal in multiple parallel channel configuration. Aided by strong evaporation rates, the bubbles nucleating on the wall grow rapidly and fill the entire channel. The contact line between the bubble base and the channel wall surface now becomes the entire perimeter at both ends of the vapor slug. Evaporation occurs at the moving contact line of the expanding vapor slug as well as over the channel wall covered with a thin evaporating film surrounding the vapor core. The usual nucleate boiling heat transfer mechanisms, including liquid film evaporation and transient heat conduction in the liquid adjacent to the contact line region, play an important role. The liquid film under the large vapor slug evaporates completely at downstream locations thus presenting a dryout condition periodically with the passage of each large vapor slug. The experimental data and high speed visual observations confirm some of the key features presented in this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microchemical systems for continuous-flow synthesis
Hartman, R. L., & Jensen, K. F. (2009) · Lab on a Chip · doi:10.1039/b906343a · Cited by 508
Boiling heat transfer in rectangular microchannels with reentrant cavities
Koşar, A., Kuo, C.-J., & Peles, Y. (2005) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2005.06.003 · Cited by 295
Metadata
- Authors
- Kandlikar, S. G.
- Venue
- Journal of Heat Transfer
- Publisher
- ASME International
- Published
- 2004-02-01
- Volume
- 126
- Issue
- 1
- Pages
- 8-16
- ISSN
- 0022-1481 (ISSN-L)
- 1528-8943
- OpenAlex
- W2068778507
- Cited by
- 459
- References
- 0
- FWCI
- 55.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heat Transfer Mechanisms During Flow Boiling in Microchannels. https://app.cochat.ai/papers/10.1115/1.1643090
- The paper
- Kandlikar, S. G. (2004). Heat Transfer Mechanisms During Flow Boiling in Microchannels. Journal of Heat Transfer. https://doi.org/10.1115/1.1643090
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.