Control-Oriented Modeling of Transcritical Vapor Compression Systems
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
This paper presents a methodology for developing a low order dynamic model of a transcritical air-conditioning system, specifically suited for multivariable controller design. An 11th-order nonlinear dynamic model of the system is derived using first principles. Analysis indicates that the system exhibits multiple time scale behavior, and that model reduction is appropriate. Model reduction using singular perturbation techniques yields physical insight as to which physical phenomena are relatively fast/slow, and a 5th-order dynamic model appropriate for multivariable controller design. Although all results shown are for a transcritical cycle, the methodology presented can easily be extended to subcritical cycles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
System Identification: Theory for the User
Lennart Ljung, A. (1987) · Cited by 17,690
Multivariable Feedback Control: Analysis and Design
Skogestad, S., & Postlethwaite, I. (1996) · Cited by 6,312
Thermodynamics : An Engineering Approach
Çengel, Y. A., & Boles, M. A. (1989) · UCLA - Biblioteca de Ciencias y Tecnologia Felix Morales Bueno · Cited by 5,747
Span, R., & Wagner, W. (1996) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555991 · Cited by 5,049 · cited 2×
“These routines are based on FORTRAN subroutines that use the equation of state [34].”
Method(1998) · doi:10.1142/3481 · Cited by 4,436
Linear System Theory and Design
Chen, C. (1995) · Medical Entomology and Zoology · Cited by 3,093
Singular Perturbation Methods in Control: Analysis and Design
Kokotović, P., Khalil, H. K., & O'Reilly, J. (1999) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611971118 · Cited by 2,485 · cited 4×
“Further explanation of this technique, as well as a proof of its validity can be found in [21] and [26].”
BackgroundMethodResultInfluentialÅström, K. J., & Bell, R. D. (2000) · Automatica · doi:10.1016/s0005-1098(99)00171-5 · Cited by 609 · cited 1×
“The same approach has also been used on other types of systems for control-oriented modeling (see Aström’s work on drum boiler dynamics [3]).”
MethodA simulation model of the transient performance of a heat pump
Chi, J., & Didion, D. A. (1982) · International Journal of Refrigeration · doi:10.1016/0140-7007(82)90099-8 · Cited by 209 · cited 1×
“Chi and Didion also present a dynamic model of a complete vapor compression cycle using a moving boundary, lumped parameter formulation [10].”
MethodMultivariable Control of Vapor Compression Systems
He, X.-D., Liu, S., Asada, H. H., & Itoh, H. (1998) · HVAC&R Research · doi:10.1080/10789669.1998.10391401 · Cited by 185 · cited 2×
“He’s dissertation [15] and two journal articles [16] and [17].”
BackgroundMethodController design: moving from theory to practice
Anderson, B. D. O. (1993) · IEEE Control Systems · doi:10.1109/37.229554 · Cited by 152 · cited 1×
“3 Anderson in [2].”
MacArthur, J. W., & Grald, E. W. (1989) · International Journal of Refrigeration · doi:10.1016/0140-7007(89)90009-1 · Cited by 147 · cited 1×
“Later these models were compared to experimental data [25].”
ResultSingular Perturbation Methodology in Control Systems
Naidu (1988) · Cited by 135
Wedekind, G. L., Bhatt, B. L., & Beck, B. T. (1978) · International Journal of Multiphase Flow · doi:10.1016/0301-9322(78)90029-0 · Cited by 122 · cited 1×
“In 1978 he proposed using a mean void fraction to develop a transient model for the evaporating and condensing flows of a vapor compression system [4,37].”
MethodTransient heat pump behaviour: a theoretical investigation
MacArthur, J. W. (1984) · International Journal of Refrigeration · doi:10.1016/0140-7007(84)90025-2 · Cited by 93 · cited 1×
“MacArthur used a distributed formulation for modeling these systems and presented simulation results in [24].”
MethodDynamic modeling and multivariable control of vapor compression cycles in air conditioning systems
He, X. (1996) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 71
Heat Transfer and Pressure Drop for Flow of Supercritical and Subcritical CO2 in Microchannel Tubes
Pettersen, J., Rieberer, R., & Munkejord, S. T. (2000) · Defense Technical Information Center (DTIC) · Cited by 48
Performance of the Prototype of a Transcritical R744 Mobile A/C System
McEnaney, R. P., Park, Y. C., Yin, J., & Hrnjak, P. (1999) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/1999-01-0872 · Cited by 47
Cited by
A dynamic model of a vapor compression cycle with shut-down and start-up operations
Li, B., & Alleyne, A. G. (2010) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2009.09.011 · Cited by 178
Self-citationModelling and optimal energy-saving control of automotive air-conditioning and refrigeration systems
Huang, Y., Khajepour, A., Bagheri, F., & Bahrami, M. (2017) · Proceedings of the Institution of Mechanical Engineers, Part D: Journal of Automobile Engineering · doi:10.1177/0954407016636978 · Cited by 44
“…with the fluid quality; it is defined as the ratio of the vapour mass to the total mass entering the heat exchangers and is calculated from 15,19 (cid:2) g = where S is the slip ratio defined as the ratio of the vapour velocity to the liquid velocity in the two-phase sections and is…”
Background
Metadata
- Authors
- Rasmussen, B. P., & Alleyne, A. G.
- Venue
- Journal of Dynamic Systems, Measurement, and Control
- Publisher
- ASME International
- Published
- 2004-03-01
- Volume
- 126
- Issue
- 1
- Pages
- 54-64
- ISSN
- 0022-0434 (ISSN-L)
- 1528-9028
- OpenAlex
- W2026902989
- Cited by
- 176
- References
- 18
- FWCI
- 16.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.