Creep Does Not Contribute to Fatigue in Bovine Trabecular Bone
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
In both cortical and trabecular bone loaded in fatigue, the stress-strain loops translate along the strain axis. Previous studies have suggested that this translation is the result of creep associated with the mean stress applied in the fatigue test. In this study, we measured the residual strain (corresponding to the translation of the stress-strain loops) in fatigue tests on bovine trabecular bone and compared it to an upper bound estimate of the creep strain in each test. Our results indicate that the contribution of creep to the translation of the stress-strain loops is negligible in bovine trabecular bone. These results, combined with models for fatigue in lower density bone, suggest that that creep does not contribute to the fatigue of normal human bone. Creep may make a significant contribution to fatigue in low-density osteoporotic bone in which trabeculae have resorbed, reducing the connectivity of the trabecular structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Cyclic mechanical property degradation during fatigue loading of cortical bone
Pattin, C. A., Caler, W. E., & Carter, D. R. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00156-1 · Cited by 442
Bone creep-fatigue damage accumulation
Caler, W. E., & Carter, D. R. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90013-4 · Cited by 263
Failure mechanisms in human vertebral cancellous bone
Fyhrie, D. P., & Schaffler, M. B. (1994) · Bone · doi:10.1016/8756-3282(94)90900-8 · Cited by 215
Tensile Fatigue in Bone: Are Cycles-, or Time to Failure, or Both, Important?
ZIOUPOS, P., CURREY, J. D., & CASINOS, A. (2001) · Journal of Theoretical Biology · doi:10.1006/jtbi.2001.2316 · Cited by 81
Fatigue Microdamage in Bovine Trabecular Bone
Moore, T. L. A., & Gibson, L. J. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1631584 · Cited by 47
Self-citation
Cited by
Harley, B. A. C., Kim, H.-D., Zaman, M. H., Yannas, I. V., Lauffenburger, D. A., & Gibson, L. J. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.122598 · Cited by 359
Self-citationCompressive fatigue behavior of human vertebral trabecular bone
Rapillard, L., Charlebois, M., & Zysset, P. K. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.04.033 · Cited by 113
“effects are negligible under low cycle fatigue tests (Moore et al., 2004).”
BackgroundAnisotropy of the fatigue behaviour of cancellous bone
Dendorfer, S., Maier, H. J., Taylor, D., & Hammer, J. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.037 · Cited by 76
Yamamoto, E., Paul Crawford, R., Chan, D. D., & Keaveny, T. M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.017 · Cited by 72
“, 1980) and fatigue (Bowman et al., 1998; Haddock et al., 2004; Michel et al., 1993; Moore and Gibson, 2003a; Moore et al., 2004) of trabecular bone.”
BackgroundModeling the onset and propagation of trabecular bone microdamage during low-cycle fatigue
Kosmopoulos, V., Schizas, C., & Keller, T. S. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.10.020 · Cited by 44
Metadata
- Authors
- Moore, T. L. A., O’Brien, F. J., & Gibson, L. J.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2004-06-01
- Volume
- 126
- Issue
- 3
- Pages
- 321-329
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2013873167
- Cited by
- 37
- References
- 6
- FWCI
- 3.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.