The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The Use of a Universal Force-Moment Sensor to Determine In-Situ Forces in Ligaments: A New Methodology
Abstract
Determination of ligament forces is an integral part of understanding their contribution during motion and external loading of an intact joint. While almost all previous investigations have reported only the magnitude of tension, this alone cannot adequately describe the function of a particular ligament. An alternative approach to determine the in-situ forces in ligaments has been developed which utilizes a universal force-moment sensor in conjunction with a force transformation scheme. In addition to providing the magnitude of ligament force, the direction and point of application of this in-situ force can also be determined. Further, the approach does not require mechanical contact with the ligament. Application of this new methodology is demonstrated for the human anterior cruciate ligament in the present study (n = 7) although it may be similarly applied to other ligaments at the knee or in other synovial joints of the human body.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Markolf, K. L., Gorek, J. F., Kabo, J. M., & Shapiro, M. S. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072040-00014 · Cited by 610
Cited by
Biomechanical Analysis of an Anatomic Anterior Cruciate Ligament Reconstruction
Yagi, M., Wong, E. K., Kanamori, A., Debski, R. E., Fu, F. H., & Woo, S. L.-Y. (2002) · The American Journal of Sports Medicine · doi:10.1177/03635465020300050501 · Cited by 988
Self-citationEffects of Increasing Tibial Slope on the Biomechanics of the Knee
Giffin, J. R., Vogrin, T. M., Zantop, T., Woo, S. L.-Y., & Harner, C. D. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503258880 · Cited by 854
Self-citationLoh, J. C., Fukuda, Y., Tsuda, E., Steadman, R. J., Fu, F. H., & Woo, S. L.-Y. (2003) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2003.50084 · Cited by 706
Self-citationDistribution of in situ forces in the anterior cruciate ligament in response to rotatory loads
Gabriel, M. T., Wong, E. K., Woo, S. L., Yagi, M., & Debski, R. E. (2004) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(03)00133-5 · Cited by 673
Self-citationSakane, M., Fox, R. J., Glen, S. L. W., Livesay, A., Li, G., & Fu, F. H. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150219 · Cited by 559
Metadata
- Authors
- Fujie, H., Livesay, G. A., Woo, S. L.-Y., Kashiwaguchi, S., & Blomstrom, G.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1995-02-01
- Volume
- 117
- Issue
- 1
- Pages
- 1-7
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W1989217949
- Cited by
- 233
- References
- 1
- FWCI
- 5.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Use of a Universal Force-Moment Sensor to Determine In-Situ Forces in Ligaments: A New Methodology. https://app.cochat.ai/papers/10.1115/1.2792266
- The paper
- Fujie, H., Livesay, G. A., Woo, S. L.-Y., Kashiwaguchi, S., & Blomstrom, G. (1995). The Use of a Universal Force-Moment Sensor to Determine In-Situ Forces in Ligaments: A New Methodology. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2792266
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.