The DOI matches its Crossref record.
A Fibril-Network-Reinforced Biphasic Model of Cartilage in Unconfined Compression
Abstract
Cartilage mechanical function relies on a composite structure of a collagen fibrillar network entrapping a proteoglycan matrix. Previous biphasic or poroelastic models of this tissue, which have approximated its composite structure using a homogeneous solid phase, have experienced difficulties in describing measured material responses. Progress to date in resolving these difficulties has demonstrated that a constitutive law that is successful for one test geometry (confined compression) is not necessarily successful for another (unconfined compression). In this study, we hypothesize that an alternative fibril-reinforced composite biphasic representation of cartilage can predict measured material responses and explore this hypothesis by developing and solving analytically a fibril-reinforced biphasic model for the case of uniaxial unconfined compression with frictionless compressing platens. The fibrils were considered to provide stiffness in tension only. The lateral stiffening provided by the fibril network dramatically increased the frequency dependence of disk rigidity in dynamic sinusoidal compression and the magnitude of the stress relaxation transient, in qualitative agreement with previously published data. Fitting newly obtained experimental stress relaxation data to the composite model allowed extraction of mechanical parameters from these tests, such as the rigidity of the fibril network, in addition to the elastic constants and the hydraulic permeability of the remaining matrix. Model calculations further highlight a potentially important difference between homogeneous and fibril-reinforced composite models. In the latter type of model, the stresses carried by different constituents can be dissimilar, even in sign (compression versus tension) even though strains can be identical. Such behavior, resulting only from a structurally physiological description, could have consequences in the efforts to understand the mechanical signals that determine cellular and extracellular biological responses to mechanical loads in cartilage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chung, C., & Burdick, J. A. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.027 · Cited by 760
Cartilage Tissue Remodeling in Response to Mechanical Forces
Grodzinsky, A. J., Levenston, M. E., Jin, M., & Frank, E. H. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.691 · Cited by 642
The role of interstitial fluid pressurization in articular cartilage lubrication
Ateshian, G. A. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.04.040 · Cited by 533
Mechano-Electrochemical Properties Of Articular Cartilage: Their Inhomogeneities and Anisotropies
Mow, V. C., & Guo, X. E. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.110701.120309 · Cited by 478
Korhonen, R. K., Laasanen, M. S., Töyräs, J., Rieppo, J., Hirvonen, J., Helminen, H. J., & Jurvelin, J. S. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00052-0 · Cited by 464
Metadata
- Authors
- Soulhat, J., Buschmann, M. D., & Shirazi-Adl, A.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1999-06-01
- Volume
- 121
- Issue
- 3
- Pages
- 340-347
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2022805915
- Cited by
- 250
- References
- 0
- FWCI
- 8.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Fibril-Network-Reinforced Biphasic Model of Cartilage in Unconfined Compression. https://app.cochat.ai/papers/10.1115/1.2798330
- The paper
- Soulhat, J., Buschmann, M. D., & Shirazi-Adl, A. (1999). A Fibril-Network-Reinforced Biphasic Model of Cartilage in Unconfined Compression. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2798330
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.