The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Convergence Behavior of High-Resolution Finite Element Models of Trabecular Bone
Abstract
The convergence behavior of finite element models depends on the size of elements used, the element polynomial order, and on the complexity of the applied loads. For high-resolution models of trabecular bone, changes in architecture and density may also be important. The goal of this study was to investigate the influence of these factors on the convergence behavior of high-resolution models of trabecular bone. Two human vertebral and two bovine tibial trabecular bone specimens were modeled at four resolutions ranging from 20 to 80 μm and subjected to both compressive and shear loading. Results indicated that convergence behavior depended on both loading mode (axial versus shear) and volume fraction of the specimen. Compared to the 20 μm resolution, the differences in apparent Young’s modulus at 40 μm resolution were less than 5 percent for all specimens, and for apparent shear modulus were less than 7 percent. By contrast, differences at 80 μm resolution in apparent modulus were up to 41 percent, depending on the specimen tested and loading mode. Overall, differences in apparent properties were always less than 10 percent when the ratio of mean trabecular thickness to element size was greater than four. Use of higher order elements did not improve the results. Tissue level parameters such as maximum principal strain did not converge. Tissue level strains converged when considered relative to a threshold value, but only if the strains were evaluated at Gauss points rather than element centroids. These findings indicate that good convergence can be obtained with this modeling technique, although element size should be chosen based on factors such as loading mode, mean trabecular thickness, and the particular output parameter of interest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Cited by
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
Self-citationComparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00257-4 · Cited by 1,142
Self-citationBiomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Self-citationPistoia, W., van Rietbergen, B., Lochmüller, E.-M., Lill, C. A., Eckstein, F., & Rüegsegger, P. (2002) · Bone · doi:10.1016/s8756-3282(02)00736-6 · Cited by 643
Niebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., & Keaveny, T. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00149-4 · Cited by 431
Self-citation
Metadata
- Authors
- Niebur, G. L., Yuen, J. C., Hsia, A. C., & Keaveny, T. M.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1999-12-01
- Volume
- 121
- Issue
- 6
- Pages
- 629-635
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2098553910
- Cited by
- 165
- References
- 1
- FWCI
- 4.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.