Abstract

Systematic studies of continuous fin-and-tube tube heat exchangers under dehumidifying conditions are reported in the present study. The heat exchangers consist of nine fin-and-tube heat exchangers having plane fins. The effects of fin spacing, the number of tube row, and inlet conditions are investigated. Data are presented in terms of j factors and friction factors f. It is found that the inconsistencies in the open literature may be associated with the wet fin efficiency. A correlation is proposed for the present plate fin configuration; this correlation can describe 92 percent of j, and 91 percent of the f data within ±10 percent.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1115/1.2824075

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 187

Metadata

Authors
Wang, C.-C., Hsieh, Y.-C., & Lin, Y.-T.
Venue
Journal of Heat Transfer
Published
1997-02-01
Volume
119
Issue
1
Pages
109-117
ISSN
  • 0022-1481 (ISSN-L)
  • 1528-8943
OpenAlex
W2011467654
Cited by
187
References
17
FWCI
17.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance of Plate Finned Tube Heat Exchangers Under Dehumidifying Conditions. https://app.cochat.ai/papers/10.1115/1.2824075
The paper
Wang, C.-C., Hsieh, Y.-C., & Lin, Y.-T. (1997). Performance of Plate Finned Tube Heat Exchangers Under Dehumidifying Conditions. Journal of Heat Transfer. https://doi.org/10.1115/1.2824075

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.