Air-side performance of brazed aluminum heat exchangers under dehumidifying conditions
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
For smaller louver angles (Lα < 27°), the sensible heat transfer coefficient for all fin pitches is smaller than that of a dry surface.
“for smaller louver angles ( L α < 27 ∘ ), the sensible heat transfer coefficient for all fin pitches is smaller than that of a dry surface.”
As louver angle decreased, the amount of condensed water increased and fin and louver bridging became more obvious.
“This proved that as the louver angle decreased, the amount of condensed water increased and the fin and louver bridging became more obvious.”
For heat exchangers with small fin pitch (Fp < 1.4 mm) and large louver angles (Lα = 27°), the sensible heat transfer coefficient and friction are greater than those for dry surfaces for all operating conditions.
“The heat exchangers have small fin pitch ( Fp < 1 . 4 mm ) and large louver angles ( L α = 27 ∘ ), and the sensible heat transfer coefficient and friction are greater than those for dry surfaces for all operating conditions.”
Correlations for the j factor and f factor were proposed by Kim and Bullard through the testing of 30 samples under wet conditions.
“Based on Chang and Wang ' s equation [108], the correlations for the j factor and f factor were proposed by Kim and Bullard [83] through the testing of 30 samples under wet conditions.”
At constant flow depth 20 mm, for fin pitches 1.0, 1.2, 1.4 mm, air-side heat transfer coefficient for dry conditions and sensible heat transfer coefficient for wet conditions increase as Reynolds number varies from 80 to 300.
“at a constant flow depth of 20 mm, for fin pitches of 1.0, 1.2 and 1.4 mm, the air-side heat transfer coefficient for dry conditions and sensible heat transfer coefficient for wet conditions increased as Reynolds number varied from 80 to 300.”
Enhanced thermal performance at high Reynolds number is due to increased mixing generated by streamwise vorticity of condensation water.
“the enhanced thermal performance at high Reynolds number was due to the increased mixing generated by the stream wise vorticity of condensation water.”
At low Reynolds numbers, heat transfer decreases due to increased thermal resistance.
“at low Reynolds numbers, heat transfer decreased due to increased thermal resistance”
Cites
Air-side thermal hydraulic performance of multi-louvered fin aluminum heat exchangers
Kim, M.-H., & Bullard, C. W. (2002) · International Journal of Refrigeration · doi:10.1016/s0140-7007(01)00025-1 · Cited by 280 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Patil, M. S., Seo, J.-H., & Lee, M.-Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.107 · Cited by 86 · see citing works
Ma, X., Ding, G., Zhang, Y., & Wang, K. (2007) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2007.03.001 · Cited by 82 · see citing works
Zhang, P., & Hrnjak, P. S. (2009) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2008.11.006 · Cited by 75 · see citing works
Ayad, F., Benelmir, R., & Idris, M. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2020.116218 · Cited by 30 · see citing works
PADHMANABHAN, S., CREMASCHI, L., & FISHER, D. (2011) · International Journal of Air-Conditioning and Refrigeration · doi:10.1142/s2010132511000600 · Cited by 29 · see citing works
Xiong, T., Liu, G., Gao, Q., Yan, G., & Yu, J. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105654 · Cited by 26 · see citing works
- Authors
- Kim, M.-H., & Bullard, C. W.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- Corresponding author
- Kim, Man-Hoe
- ORCID
- Kim, Man-Hoe
- Venue
- International Journal of Refrigeration
- Publisher
- Elsevier BV
- Published
- 2002-11
- Volume
- 25
- Issue
- 7
- Pages
- 924-934
- ISSN
- 0140-7007 (ISSN-L)
- OpenAlex
- W2075664650
- Cited by
- 116
- References
- 1
- Citations by year
- 2026: 3 · 2025: 8 · 2024: 2 · 2023: 7 · 2022: 11 · 2021: 5 · 2020: 7 · 2019: 6 · 2018: 7 · 2017: 7 · 2016: 12 · 2015: 5 · 2014: 2 · 2013: 2 · 2012: 6
- FWCI
- 5.09
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Refrigeration (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer Mechanisms
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- louvered fin heat exchanger, friction factor, cross-flow heat exchanger, effectiveness-NTU method, heat transfer correlations, pressure drop
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review