The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Condensation in Smooth Horizontal Tubes
Abstract
An experimental study of heat transfer and flow regimes during condensation of refrigerants in horizontal tubes was conducted. Measurements were made in smooth, round tubes with diameters ranging from 3.14 mm to 7.04 mm. The refrigerants tested were R-12, R-22, R-134a, and near-azeotropic blends of R-32/R-125 in 50 percent/50 percent and 60 percent/40 percent compositions. The study focused primarily on measurement and prediction of condensing heat transfer coefficients and the relationship between heat transfer coefficients and two-phase flow regimes. Flow regimes were observed visually at the inlet and outlet of the test condenser as the heat transfer data were collected. Stratified, wavy, wavy annular, annular, annular mist, and slug flows were observed. True mist flow without a stable wall film was not observed during condensation tests. The experimental results were compared with existing flow regime maps and some corrections are suggested. The heat transfer behavior was controlled by the prevailing flow regime. For the purpose of analyzing condensing heat transfer behavior, the various flow regimes were divided into two broad categories of gravity-dominated and shear-dominated flows. In the gravity dominated flow regime, the dominant heat transfer mode was laminar film condensation in the top of the tube. This regime was characterized by heat transfer coefficients that depended on the wall-to-refrigerant temperature difference but were nearly independent of mass flux. In the shear-dominated flow regime, forced-convective condensation was the dominant heat transfer mechanism. This regime was characterized by heat transfer coefficients that were independent of temperature difference but very dependent on mass flux and quality. Heat transfer correlations that were developed for each of these flow regimes successfully predicted data from the present study and from several other sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Describing the uncertainties in experimental results
Moffat, R. J. (1988) · Experimental Thermal and Fluid Science · doi:10.1016/0894-1777(88)90043-x · Cited by 9,860
A model for predicting flow regime transitions in horizontal and near horizontal gas‐liquid flow
Taitel, Y., & Dukler, A. E. (1976) · AIChE Journal · doi:10.1002/aic.690220105 · Cited by 2,915
Proposed Correlation of Data for Isothermal Two-Phase, Two-Component Flow in Pipes
Lockhart, R. W. (1949) · Chemical engineering progress · Cited by 2,727
Heat transfer in automobile radiators of the tubular type
Dittus, F. W., & Boelter, L. M. K. (1985) · International Communications in Heat and Mass Transfer · doi:10.1016/0735-1933(85)90003-x · Cited by 2,407
A general correlation for heat transfer during film condensation inside pipes
Shah, M. M. (1979) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(79)90058-9 · Cited by 1,592
A flow pattern map for gas—liquid flow in horizontal pipes
Mandhane, J. M., Gregory, G. A., & Aziz, K. (1974) · International Journal of Multiphase Flow · doi:10.1016/0301-9322(74)90006-8 · Cited by 1,335
Die Oberflachenkondensation des Wasserdampfes
Nußelt, W. (1916) · Medical Entomology and Zoology · Cited by 973
Zivi, S. M. (1964) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.3687113 · Cited by 915
Heat Transfer in Automobile Radiators of the Tubular Type
Dittus, F. W. (1930) · Medical Entomology and Zoology · Cited by 827
Cited by
Condensation in horizontal tubes, part 2: new heat transfer model based on flow regimes
Thome, J. R., El Hajal, J., & Cavallini, A. (2003) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(03)00140-6 · Cited by 592
Condensation in Horizontal Smooth Tubes: A New Heat Transfer Model for Heat Exchanger Design
Cavallini, A., Col, D. D., Doretti, L., Matkovic, M., Rossetto, L., Zilio, C., & Censi, G. (2006) · Heat Transfer Engineering · doi:10.1080/01457630600793970 · Cited by 546
Condensation in horizontal tubes, part 1: two-phase flow pattern map
El Hajal, J., Thome, J. R., & Cavallini, A. (2003) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(03)00139-x · Cited by 537
Two-Phase Flow, Boiling, and Condensation: In Conventional and Miniature Systems
Ghiaasiaan, S. M. (2017) · Cambridge University Press eBooks · doi:10.1017/9781316597392 · Cited by 286
Kim, S.-M., & Mudawar, I. (2014) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2014.05.036 · Cited by 260
Metadata
- Authors
- Dobson, M. K., & Chato, J. C.
- Venue
- Journal of Heat Transfer
- Publisher
- ASME International
- Published
- 1998-02-01
- Volume
- 120
- Issue
- 1
- Pages
- 193-213
- ISSN
- 0022-1481 (ISSN-L)
- 1528-8943
- OpenAlex
- W2056320887
- Cited by
- 804
- References
- 13
- FWCI
- 23.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Condensation in Smooth Horizontal Tubes. https://app.cochat.ai/papers/10.1115/1.2830043
- The paper
- Dobson, M. K., & Chato, J. C. (1998). Condensation in Smooth Horizontal Tubes. Journal of Heat Transfer. https://doi.org/10.1115/1.2830043
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.