Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 546

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Condensation in Horizontal Smooth Tubes: A New Heat Transfer Model for Heat Exchanger Design

Cavallini, Alberto, Col, Davide Del, Doretti, Luca, Matkovic, Marko, Rossetto, Luisa, Zilio, Claudio, Censi, Giuseppe · 2006 · Heat Transfer Engineering

Abstract

This paper proposes a new method to determine the condensation heat transfer coefficient of fluids flowing into horizontal smooth tubes with internal diameters D > 3 mm. The method has been drawn up as simply as possible and is ready to use in heat exchanger modeling and design applications. It is also suitable to work very well with old and new fluids used in the refrigeration, air conditioning, and heat pump industries. Particular attention is given to accuracy: it has been tested over a wide updated experimental database and comes from many different independent researchers with reduced experimental uncertainties. In order to obtain an easy structure, only two equations are employed, related respectively to & Delta; T-independent and to & Delta; T-dependent fluid flows. All the parameters that influence the condensation heat transfer have been included. A comparison has been conducted against HCFCs, HFCs, HCs, carbon dioxide, ammonia, and water data. Zeotropic mixtures with two and three components are also considered in the comparison by applying the Bell and Ghaly [1 Bell, K. J. and Ghaly, M. A. 1973. An Approximate Generalized Design Method for Multicomponent/Partial Condenser. AIChE Symp. Ser., vol. 69: 72–79. [CSA] [Google Scholar]] correction to calculate the relative heat transfer penalization. A model has been developed with the idea of getting high accuracy through an easy structure, and the results show a very satisfactory agreement with experimental data: average deviation eR = +2%, absolute mean deviation eAB = 14%, and standard deviation σN = 19% for the total number of 5478 data points.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/01457630600793970

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 546

Metadata

Authors
Cavallini, A., Col, D. D., Doretti, L., Matkovic, M., Rossetto, L., Zilio, C., & Censi, G.
Venue
Heat Transfer Engineering
Published
2006-09
Volume
27
Issue
8
Pages
31-38
ISSN
  • 0145-7632 (ISSN-L)
  • 1521-0537
OpenAlex
W1995066522
Cited by
546
References
6
FWCI
9.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Condensation in Horizontal Smooth Tubes: A New Heat Transfer Model for Heat Exchanger Design. https://app.cochat.ai/papers/10.1080/01457630600793970
The paper
Cavallini, A., Col, D. D., Doretti, L., Matkovic, M., Rossetto, L., Zilio, C., & Censi, G. (2006). Condensation in Horizontal Smooth Tubes: A New Heat Transfer Model for Heat Exchanger Design. Heat Transfer Engineering. https://doi.org/10.1080/01457630600793970

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.