Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 166

The DOI matches its Crossref record.

Dynamic Lumped Element Response of the Human Fingerpad

Pawluk, D. T. V., Howe, R. D. · 1999 · Journal of Biomechanical Engineering

Abstract

The dynamic response of the fingerpad plays an important role in the tactile sensory response and precision manipulation, as well as in ergonomic design. This paper investigates the dynamic lumped element response of the human fingerpad in vivo to a compressive load. A flat probe indented the fingerpad at a constant velocity, then held a constant position. The resulting force (0–2 N) increased rapidly with indentation, then relaxed during the hold phase. A quasilinear viscoelastic model successfully explained the experimental data. The instantaneous elastic response increased exponentially with position, and the reduced relaxation function included three decaying exponentials (with time constants of approximately 4 ms, 70 ms, and 1.4 s) plus a constant. The model was confirmed with data from sinusoidal displacement trajectories.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1115/1.2835100

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 166

Metadata

Authors
Pawluk, D. T. V., & Howe, R. D.
Venue
Journal of Biomechanical Engineering
Published
1999-04-01
Volume
121
Issue
2
Pages
178-183
ISSN
  • 0148-0731 (ISSN-L)
  • 1528-8951
OpenAlex
W2069940518
Cited by
166
References
0
FWCI
3.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dynamic Lumped Element Response of the Human Fingerpad. https://app.cochat.ai/papers/10.1115/1.2835100
The paper
Pawluk, D. T. V., & Howe, R. D. (1999). Dynamic Lumped Element Response of the Human Fingerpad. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2835100

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.