The Effect of Strain Rate on the Mechanical Properties of Human Cortical Bone
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Bone mechanical properties are typically evaluated at relatively low strain rates. However, the strain rate related to traumatic failure is likely to be orders of magnitude higher and this higher strain rate is likely to affect the mechanical properties. Previous work reporting on the effect of strain rate on the mechanical properties of bone predominantly used nonhuman bone. In the work reported here, the effect of strain rate on the tensile and compressive properties of human bone was investigated. Human femoral cortical bone was tested longitudinally at strain rates ranging between 0.14–29.1s−1 in compression and 0.08–17 s−1 in tension. Young’s modulus generally increased, across this strain rate range, for both tension and compression. Strength and strain (at maximum load) increased slightly in compression and decreased (for strain rates beyond 1 s−1) in tension. Stress and strain at yield decreased (for strain rates beyond 1 s−1) for both tension and compression. In general, there seemed to be a relatively simple linear relationship between yield properties and strain rate, but the relationships between postyield properties and strain rate were more complicated and indicated that strain rate has a stronger effect on postyield deformation than on initiation of yielding. The behavior seen in compression is broadly in agreement with past literature, while the behavior observed in tension may be explained by a ductile to brittle transition of bone at moderate to high strain rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533
In vivo measurement of human tibial strains during vigorous activity
Burr, D. B., Milgrom, C., Fyhrie, D., Forwood, M., Nyska, M., Finestone, A., Hoshaw, S., Saiag, E., & Simkin, A. (1996) · Bone · doi:10.1016/8756-3282(96)00028-2 · Cited by 712
Bone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709
Dynamic response of bone and muscle tissue.
McElhaney, J. H. (1966) · Journal of Applied Physiology · doi:10.1152/jappl.1966.21.4.1231 · Cited by 509
Reilly, D. T., Burstein, A. H., & Frankel, V. H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90018-9 · Cited by 504
Rubin, C. T., & Lanyon, L. E. (1982) · Journal of Experimental Biology · doi:10.1242/jeb.101.1.187 · Cited by 498
Bone Deformation Recorded in vivo from Strain Gauges Attached to the Human Tibial Shaft
Lanyon, L. E., Hampson, W. G. J., Goodship, A. E., & Shah, J. S. (1975) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677508989216 · Cited by 475
Currey, J. D. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90046-9 · Cited by 182
Self-citationWright, T. M., & Hayes, W. C. (1976) · Medical & Biological Engineering · doi:10.1007/bf02477046 · Cited by 179
Zioupos, P., Currey, J. D., & Sedman, A. J. (1994) · Medical Engineering & Physics · doi:10.1016/1350-4533(94)90039-6 · Cited by 162
Self-citationThe response of compact bone in tension at various strain rates
Crowninshield, R. D., & Pope, M. H. (1974) · Annals of Biomedical Engineering · doi:10.1007/bf02368492 · Cited by 140
Factors affecting the elasticity of bone.
SMITH, J. W., & WALMSLEY, R. (1959) · Europe PMC (PubMed Central) · Cited by 132
Evans, F. G., & Vincentelli, R. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90064-5 · Cited by 128
Evans, G. P., Behiri, J. C., Vaughan, L. C., & Bonfield, W. (1992) · Equine Veterinary Journal · doi:10.1111/j.2042-3306.1992.tb02796.x · Cited by 80
Dynamic response of biological materials.
Byars, E. F., & McElhaney, J. H. (1965) · NASA Technical Reports Server (NASA) · Cited by 78
Relations between tensile impact properties and microstructure of compact bone
Saha, S., & Hayes, W. C. (1977) · Calcified Tissue International · doi:10.1007/bf02223298 · Cited by 74
Compressive strength of mandibular bone as a function of microstructure and strain rate
Robertson, D. M., & Smith, D. C. (1978) · Journal of Biomechanics · doi:10.1016/0021-9290(78)90057-x · Cited by 65
Pithioux, M., Subit, D. L., & Chabrand, P. R. (2004) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.05.002 · Cited by 54
Tensile impact properties of human compact bone
Saha, S., & Hayes, W. C. (1976) · Journal of Biomechanics · doi:10.1016/0021-9290(76)90010-5 · Cited by 44
Instrumented tensile-impact tests of bone
Saha, S., & Hayes, W. C. (1974) · Experimental Mechanics · doi:10.1007/bf02323147 · Cited by 32
Cited by
Allen, M. R., & Burr, D. B. (2011) · Bone · doi:10.1016/j.bone.2010.10.159 · Cited by 219
Zimmermann, E. A., Gludovatz, B., Schaible, E., Busse, B., & Ritchie, R. O. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.03.066 · Cited by 163
“02 s 1 during sprinting or downhill running [27e29]; other studies simulating a fall have shown that it takesw6e10ms for a falling femur to reach the peak load once it has begun to make contact with the ground [30], with an upper bound for these high strain rates to be w25 s 1 for very high impacts [31].”
BackgroundResultZioupos, P., Hansen, U., & Currey, J. D. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.07.025 · Cited by 156
“In this context the ductile-to-brittle transition of cortical femoral bone with the strain rate (Hansen et al., 2008) generated two legitimate further questions that needed answering.”
BackgroundMethodSelf-citationOsseodensification technique in crestal maxillary sinus elevation—A narrative review
Gaspar, J., Mazor, Z., & Bonfante, E. A. (2025) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.13399 · Cited by 17
Metadata
- Authors
- Hansen, U., Zioupos, P., Simpson, R., Currey, J. D., & Hynd, D.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2008-02-01
- Volume
- 130
- Issue
- 1
- Pages
- 011011-011011
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W1983885772
- Cited by
- 234
- References
- 20
- FWCI
- 6.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.