Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 470

The DOI matches its Crossref record.

Application of the Joint Coordinate System to Three-Dimensional Joint Attitude and Movement Representation: A Standardization Proposal

Cole, G. K., Nigg, B. M., Ronsky, J. L., Yeadon, M. R.·1993·Journal of Biomechanical Engineering

Abstract

The selection of an appropriate and/or standardized method for representing 3-D joint attitude and motion is a topic of popular debate in the field of biomechanics. The joint coordinate system (JCS) is one method that has seen considerable use in the literature. The JCS consists of an axis fixed in the proximal segment, an axis fixed in the distal segment, and a “floating” axis. There has not been general agreement in the literature on how to select the body fixed axes of the JCS. The purpose of this paper is to propose a single definition of the body fixed axes of the JCS. The two most commonly used sets of body fixed axes are compared and the differences between them quantified. These differences are shown to be relevant in terms of practical applications of the JCS. Argumentation is provided to support a proposal for a standardized selection of body fixed axes of the JCS consisting of the axis eˆ1 embedded in the proximal segment and chosen to represent flexion-extension, the “floating” axis eˆ2 chosen to represent ad-abduction, and the axis eˆ3 embedded in the distal segment and chosen to represent axial rotation of that segment. The algorithms for the JCS are then documented using generalized terminology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1115/1.2895496

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 470

Metadata

Authors
Cole, G. K., Nigg, B. M., Ronsky, J. L., & Yeadon, M. R.
Venue
Journal of Biomechanical Engineering
Published
1993-11-01
Volume
115
Issue
4A
Pages
344-349
ISSN
  • 0148-0731 (ISSN-L)
  • 1528-8951
OpenAlex
W1988812042
Cited by
470
References
0
FWCI
1.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Application of the Joint Coordinate System to Three-Dimensional Joint Attitude and Movement Representation: A Standardization Proposal. https://app.cochat.ai/papers/10.1115/1.2895496
The paper
Cole, G. K., Nigg, B. M., Ronsky, J. L., & Yeadon, M. R. (1993). Application of the Joint Coordinate System to Three-Dimensional Joint Attitude and Movement Representation: A Standardization Proposal. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2895496

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.