Cited by 82Spacecraft and Cryogenic TechnologiesPhase Change Materials ResearchHydrogen Storage and Materials

Analysis and Optimization of Thermal Stratification and Self-Pressurization Effects in Liquid Hydrogen Storage Systems—Part 1: Model Development

Gursu, S., Sherif, S. A., Veziroglu, T. N., Sheffield, J. W.·1993·Journal of Energy Resources Technology

Abstract

This paper reports on analyses and optimization studies of problems associated with liquid hydrogen thermal stratification and self-pressurization in cryogenic vessels. Three different pressure rise models were employed to calculate the self-pressurization and boil-off rates. These are a homogeneous model, a surface-evaporation model, and a thermal stratification model. The first two models are based on the assumption that no temperature gradients exist in the tank, while the thermal stratification model takes the temperature distribution into account. Employing the thermal stratification model, temperature gradients and their effect on the pressure rise rates in liquid hydrogen tanks are analyzed.

Integrity signals

Registry

Crossref · 10.1115/1.2905997

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Heat ingress causes the vapor temperature to increase faster than that of the liquid due to the vapor's higher thermal diffusivity, resulting in heat conduction across the vapor-liquid interface and a temperature gradient in the top layer of the liquid phase with the interface at a higher temperature than the bulk liquid (thermal stratification).

    “Additionally, heat ingress causes the vapor temperature to increase faster than that of the liquid due to the vapor's higher thermal diffusivity (α = κ/ρ•c p ), resulting in heat conduction across the vapor-liquid interface, and thus a temperature gradient in the top layer of the liquid phase with the interface at a higher temperature than the bulk liquid: this is known as thermal stratification [”

    From Modelling of Liquid Hydrogen Boil-Off (2022) · cites this paper as [16]

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

Cited by 82

Authors
Gursu, S., Sherif, S. A., Veziroglu, T. N., & Sheffield, J. W.
Affiliations
  • University of Miami (US)
  • University of Florida (US)
  • Missouri University of Science and Technology (US)
Venue
Journal of Energy Resources Technology
Publisher
Wiley
Published
1993-09-01
Volume
115
Issue
3
Pages
221-227
ISSN
  • 0195-0738 (ISSN-L)
  • 1528-8994
OpenAlex
W2064803506
Cited by
82
References
0
Citations by year
2026: 8 · 2025: 12 · 2024: 9 · 2023: 5 · 2022: 7 · 2021: 6 · 2020: 2 · 2019: 3 · 2018: 4 · 2017: 7 · 2016: 1 · 2015: 3 · 2014: 1 · 2013: 2 · 2012: 1
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Locations
Journal of Energy Resources Technology (publishedVersion)
Funders
  • U.S. Department of Energy
  • University of Miami
  • Clean Energy Institute
Topics
  • Physical Sciences › Engineering › Aerospace Engineering › Spacecraft and Cryogenic Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Phase Change Materials Research
  • Physical Sciences › Materials Science › Materials Chemistry › Hydrogen Storage and Materials
Keywords
liquid hydrogen storage, thermal stratification, self-pressurization, cryogenic vessels, boil-off rate, surface evaporation, temperature gradient, homogeneous model

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review