The DOI matches its Crossref record.
The Time and History-Dependent Viscoelastic Properties of the Canine Medial Collateral Ligament
Abstract
The viscoelastic properties of the canine medial collateral ligament (MCL) were investigated. Stress-strain relationships at different strain rates, long-term stress relaxation and cyclic stress-strain curves of the MCL were obtained experimentally using a bone-MCL-bone preparation. The experimental data were used in conjunction with the quasi-linear viscoelastic theory as proposed by Fung [15] to characterize the reduced relaxation function, G(t) and elastic response σe (ε) of this tissue. It was found that the quasi-linear viscoelastic theory can adequately describe the time and history-dependent rheological properties of the canine medial collateral ligament.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluid transport and mechanical properties of articular cartilage: A review
Mow, V. C., Holmes, M. H., & Michael Lai, W. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90031-9 · Cited by 1,024
Effects of postmortem storage by freezing on ligament tensile behavior
Woo, S. L.-Y., Orlando, C. A., Camp, J. F., & Akeson, W. H. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90016-3 · Cited by 572
Self-citationSingle lamellar mechanics of the human lumbar anulus fibrosus
Holzapfel, G. A., Schulze-Bauer, C. A. J., Feigl, G., & Regitnig, P. (2005) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-004-0053-8 · Cited by 467
Thomopoulos, S., Williams, G. R., Gimbel, J. A., Favata, M., & Soslowsky, L. J. (2003) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(03)00057-3 · Cited by 467
Thomopoulos, S., Williams, G. R., & Soslowsky, L. J. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1536660 · Cited by 434
Biomechanics of knee ligaments: injury, healing, and repair
Woo, S. L.-Y., Abramowitch, S. D., Kilger, R., & Liang, R. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.10.025 · Cited by 424
Self-citationTensile and viscoelastic properties of human patellar tendon
Johnson, G. A., Tramaglini, D. M., Levine, R. E., Ohno, K., Choi, N., & L‐Y. Woo, S. (1994) · Journal of Orthopaedic Research · doi:10.1002/jor.1100120607 · Cited by 417
Viscoelastic constitutive law in large deformations
Pioletti, D. P., Rakotomanana, L. R., Benvenuti, J.-F., & Leyvraz, P.-F. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00077-3 · Cited by 288
Viscoelastic shear properties of articular cartilage and the effects of glycosidase treatments
Zhu, W., Mow, V. C., Koob, T. J., & Eyre, D. R. (1993) · Journal of Orthopaedic Research · doi:10.1002/jor.1100110602 · Cited by 280
Nonlinear Ligament Viscoelasticity
Provenzano, P., Lakes, R., Keenan, T., & Vanderby, Jr. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1408926 · Cited by 264
Castile, R. M., Skelley, N. W., Babaei, B., Brophy, R. H., & Lake, S. P. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.11.016 · Cited by 44
Metadata
- Authors
- Woo, S. L.-Y., Gomez, M. A., & Akeson, W. H.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1981-11-01
- Volume
- 103
- Issue
- 4
- Pages
- 293-298
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2071345032
- Cited by
- 271
- References
- 0
- FWCI
- 1.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.