The Relationship Between Crimp Pattern and Mechanical Response of Human Patellar Tendon-Bone Units
The DOI matches its Crossref record.
Abstract
The objectives of this study are twofold. First, to further develop the understanding of the relationship between the observed mechanical response and changes in the crimp pattern in human patellar tendon bone units. This is accomplished through the use of a specially constructed test frame and microscope system that permits observation and measurement of the crimp patterns as a function of load. Second, the results of the experimental study are used to develop a constitutive equation that includes spatial variation in the crimp pattern. The results of both the experimental and analytical study imply that local strain in the proximity of the attachment site is significantly larger than the strain in the central region of the tendon. The experimental and histological results are for specimens taken from four human bone-patellar tendon-bone units.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wang, J. H.-C. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.011 · Cited by 1,002
Butler, D. L., Kay, M. D., & Stouffer, D. C. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90019-9 · Cited by 513
Self-citationThomopoulos, S., Williams, G. R., Gimbel, J. A., Favata, M., & Soslowsky, L. J. (2003) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(03)00057-3 · Cited by 467
Functional Attachment of Soft Tissues to Bone: Development, Healing, and Tissue Engineering
Lu, H. H., & Thomopoulos, S. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124656 · Cited by 447
Butler, D. L., Grood, E. S., Noyes, F. R., Zernicke, R. F., & Brackett, K. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90090-3 · Cited by 386
Self-citation
Metadata
- Authors
- Stouffer, D. C., Butler, D. L., & Hosny, D.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1985-05-01
- Volume
- 107
- Issue
- 2
- Pages
- 158-165
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2031578961
- Cited by
- 88
- References
- 0
- FWCI
- 0.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Relationship Between Crimp Pattern and Mechanical Response of Human Patellar Tendon-Bone Units. https://app.cochat.ai/papers/10.1115/1.3138536
- The paper
- Stouffer, D. C., Butler, D. L., & Hosny, D. (1985). The Relationship Between Crimp Pattern and Mechanical Response of Human Patellar Tendon-Bone Units. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.3138536
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.