Corrosion and Deposits From Combustion of Solid Waste
The DOI matches its Crossref record.
Abstract
Combustion of solid waste in municipal incinerators has resulted in fouling and corrosion on heat transfer surfaces. The nature of these deposits and the extent of the corrosion has been investigated in a combined field and laboratory study. In addition to the elements normally found in boiler deposits, chlorine, lead, and zinc appeared in significant quantities in the incinerator deposits. Twenty specific compounds have been identified in the deposits. The presence of potassium, sulfur, chlorine, lead, and zinc in the corrosion product scale at the metal-deposit interface has been demonstrated. Corrosion resulting from the action of flue gases and accumulated deposits has been measured by means of probes exposed in large municipal incinerators. Mechanisms for the corrosion processes are suggested, and possible remedies are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bryers, R. W. (1996) · Progress in Energy and Combustion Science · doi:10.1016/0360-1285(95)00012-7 · Cited by 808
High temperature corrosion problems in waste incineration systems
Krause, H. H. (1986) · Journal of Materials for Energy Systems · doi:10.1007/bf02833571 · Cited by 97
Self-citationKrumm, L., & Galetz, M. C. (2020) · Materials and Corrosion · doi:10.1002/maco.201911091 · Cited by 8
Heat recovery—an economic benefit to hazardous waste incineration systems
Santoleri, J. J. (1983) · Journal of Heat Recovery Systems · doi:10.1016/0198-7593(83)90006-1 · Cited by 6
Metadata
- Authors
- Krause, H. H., Vaughan, D. A., & Miller, P. D.
- Venue
- Journal of Engineering for Power
- Publisher
- ASME International
- Published
- 1973-01-01
- Volume
- 95
- Issue
- 1
- Pages
- 45-52
- ISSN
- 0022-0825 (ISSN-L)
- OpenAlex
- W2083175641
- Cited by
- 35
- References
- 0
- FWCI
- 1.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.