There is emerging data that patterns of motor activity early in neonatal life can predict impairments in neuromotor development. However, current techniques to monitor infant movement mainly rely on observer scoring, a technique limited by skill, fatigue, and inter-rater reliability. Consequently, we tested the use of a lightweight, wireless, accelerometer system that measures movement and can be worn by premature babies without interfering with routine care. We hypothesized that this system would be useful in assessing motor activity, in identifying abnormal movement, and in reducing the amount of video that a clinician would need to review for abnormal movements. Ten preterm infants in the NICU were monitored for 1 h using both the accelerometer system and video. A physical therapist trained to recognize cramped-synchronized general movements scored all of the video data by labeling each abnormal movement observed. The parameters of three different computer models were then optimized based on correlating features computed from accelerometer data and the observer’s annotations. The annotations were compared to the model’s prediction on unseen data. The trained observer identified cramped-synchronized general movements in 6 of the 10 infants. The computer models attained between 70% and 90% accuracy when predicting the same observer label for each data point. Our study suggests that mini-accelerometers may prove useful as a clinical tool assessing patterns of movement in preterm infants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Activity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147 · cited 1×
“This is comparable to the removal of the DC component of the FFT used by Bao and Intille [36] given that regular samples were not available.”
Cited by
Marcroft, C., Khan, A., Embleton, N. D., Trenell, M., & Plötz, T. (2015) · Frontiers in Neurology · doi:10.3389/fneur.2014.00284 · Cited by 146
Gao, Y., Long, Y., Guan, Y., Basu, A., Baggaley, J., & Ploetz, T. (2019) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3314399 · Cited by 49
“s have been used for automated capturing and subsequent analysis of spontaneous movements of infants with a view to reproducing the GM classification without the need for a clinical observer [36]. In [37], a clinical tool based on accelerometers was used to assess motion patterns for preterm infants and it was demonst…”
Abrishami, M. S., Nocera, L., Mert, M., Trujillo-Priego, I. A., Purushotham, S., Shahabi, C., & Smith, B. A. (2019) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2019.2893223 · Cited by 46
Metadata
- Authors
- Gravem, D., Singh, M., Chen, C., Rich, J., Vaughan, J., Goldberg, K., Waffarn, F., Chou, P., Cooper, D., Reinkensmeyer, D., & Patterson, D.
- Venue
- Journal of Medical Devices
- Publisher
- ASME International
- Published
- 2012-05-14
- Volume
- 6
- Issue
- 2
- ISSN
- 1932-6181 (ISSN-L)
- 1932-619X
- OpenAlex
- W2142962877
- Cited by
- 57
- References
- 2
- FWCI
- 1.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.