Mechanical Degradation Mechanism of Membrane Electrode Assemblies in Buckling Test Under Humidity Cycles
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Membrane electrode assembly (MEA) buckling tests in microscopic clearances under humidity cycles and numerical analyses by finite element method (FEM) were conducted. The NR211 (Dupont, 25-μm thickness, equivalent weight (EW) = 1100) sandwiched between catalyst layers (CLs) was used as the MEA. Based on tensile tests of the NR211 and NR211-CL and FEM simulation of tensile tests, the Young’s modulus and yield point of CL were estimated. While the CL had a higher Young’s modulus than the NR211 in water vapor, the CL indicated a lower Young’s modulus than the NR211 in liquid water at 80 °C. The buckling tests in microscopic diameter of 200 μm in polyimide film were carried out. The heights of bulge in the NR211 and NR211-CL after five humidity cycles were measured with a laser microscope. The height of the NR211-CL was lower than that of the NR211, due to the stiffer CL and the lower swelling ratio of the NR211-CL. Moreover, when the humidity cycles were repeated less than 1000 times, cracks were formed in the CL. The stress-strain behaviors of the NR211-CL buckling test under a humidity cycle were investigated by using the FEM. When the NR211-CL swelled, higher stress was developed at the topside of bulge and topside of bulge round. These portions corresponded to the CL crack-formed portions in the buckling test. When the NR211-CL deswelled, the tensile stress was induced in the entire NR211. The mechanical degradation mechanisms were considered as follows: Firstly, cracks initiate and propagate in the CL when the MEA swells in repeating humidity cycles. Moreover, the tensile stress is induced in the polymer electrolyte membrane (PEM) under deswelling and the CL cracks propagate into the PEM from the CL, which results in pinholes in the PEM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tang, Y., Karlsson, A. M., Santare, M. H., Gilbert, M., Cleghorn, S., & Johnson, W. B. (2006) · Materials Science and Engineering: A · doi:10.1016/j.msea.2006.03.055 · Cited by 316
Cited by
New Insights into Perfluorinated Sulfonic-Acid Ionomers
Kusoglu, A., & Weber, A. Z. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00159 · Cited by 2,432
Qiu, D., Peng, L., Lai, X., Ni, M., & Lehnert, W. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.109289 · Cited by 208
Hasan, M., Goshtasbi, A., Chen, J., Santare, M. H., & Ersal, T. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0371806jes · Cited by 25
Metadata
- Authors
- Uchiyama, T., Kato, M., Ikogi, Y., & Yoshida, T.
- Venue
- Journal of Fuel Cell Science and Technology
- Publisher
- ASME International
- Published
- 2012-11-16
- Volume
- 9
- Issue
- 6
- ISSN
- 1550-624X (ISSN-L)
- 1551-6989
- OpenAlex
- W2039112642
- Cited by
- 46
- References
- 1
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical Degradation Mechanism of Membrane Electrode Assemblies in Buckling Test Under Humidity Cycles. https://app.cochat.ai/papers/10.1115/1.4007814
- The paper
- Uchiyama, T., Kato, M., Ikogi, Y., & Yoshida, T. (2012). Mechanical Degradation Mechanism of Membrane Electrode Assemblies in Buckling Test Under Humidity Cycles. Journal of Fuel Cell Science and Technology. https://doi.org/10.1115/1.4007814
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.