Crack Formation in Membrane Electrode Assembly Under Static and Cyclic Loadings
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The mechanical reliability of membrane electrode assemblies (MEAs) in polymer electrolyte fuel cells (PEFCs) is a major concern for fuel cell vehicles. Hygrothermal cyclic conditions induce mechanical stress in MEAs and cracks form under operating conditions. This paper investigates the failure mechanism of MEAs under several mechanical and environmental conditions with the aim of designing durable PEFCs. We performed static tensile tests and low-cycle fatigue tests on MEAs. During the tensile tests, the temperature and humidity of the test chamber were controlled and surface crack formation of MEAs was observed in situ by a video microscope. Low-cycle fatigue tests were performed at ambient conditions and the number of cycles to crack formation was measured. The results reveal that the temperature and the humidity affect the mechanical properties of MEA. Observations of MEAs during tensile tests reveal that cracks form on the surface of catalyst layers immediately after the MEAs yield. These results indicate that reducing the deformation mismatch between the catalyst layer and the proton exchange membrane is important for suppressing crack formation in MEAs. The results of low-cycle fatigue tests reveal that the fatigue strength of a MEA follows the Coffin–Manson law so that fatigue design of MEAs based on the Coffin–Manson law is possible. This result is valuable for designing durable PEFCs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of PEM fuel cell durability: Degradation mechanisms and mitigation strategies
Wu, J., Yuan, X. Z., Martin, J. J., Wang, H., Zhang, J., Shen, J., Wu, S., & Merida, W. (2008) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.06.006 · Cited by 1,587
A review of accelerated stress tests of MEA durability in PEM fuel cells
ZHANG, S., YUAN, X., WANG, H., MERIDA, W., ZHU, H., SHEN, J., WU, S., & ZHANG, J. (2009) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2008.10.012 · Cited by 525
Tang, Y., Karlsson, A. M., Santare, M. H., Gilbert, M., Cleghorn, S., & Johnson, W. B. (2006) · Materials Science and Engineering: A · doi:10.1016/j.msea.2006.03.055 · Cited by 316
Cited by
New Insights into Perfluorinated Sulfonic-Acid Ionomers
Kusoglu, A., & Weber, A. Z. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00159 · Cited by 2,432
Review of Advanced Materials for Proton Exchange Membrane Fuel Cells
Kraytsberg, A., & Ein-Eli, Y. (2014) · Energy & Fuels · doi:10.1021/ef501977k · Cited by 705
Qiu, D., Peng, L., Lai, X., Ni, M., & Lehnert, W. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.109289 · Cited by 208
Hasan, M., Goshtasbi, A., Chen, J., Santare, M. H., & Ersal, T. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0371806jes · Cited by 25
Metadata
- Authors
- Kai, Y., Kitayama, Y., Omiya, M., Uchiyama, T., & Kato, M.
- Venue
- Journal of Fuel Cell Science and Technology
- Publisher
- ASME International
- Published
- 2013-03-25
- Volume
- 10
- Issue
- 2
- ISSN
- 1550-624X (ISSN-L)
- 1551-6989
- OpenAlex
- W1987293503
- Cited by
- 43
- References
- 3
- FWCI
- 2.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Crack Formation in Membrane Electrode Assembly Under Static and Cyclic Loadings. https://app.cochat.ai/papers/10.1115/1.4023878
- The paper
- Kai, Y., Kitayama, Y., Omiya, M., Uchiyama, T., & Kato, M. (2013). Crack Formation in Membrane Electrode Assembly Under Static and Cyclic Loadings. Journal of Fuel Cell Science and Technology. https://doi.org/10.1115/1.4023878
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.